Mosaic fieldbus modules
Second input KO
OUT_TEST diagnostics OK
Output connected to other inputs
Output OK but input connected to
24VDC
Short circuit between photocell
test and photocell input
No response from photocell
Short circuit between photocells
MAT disconnected
Output inconsistent with feedback
Connection incorrect
Output stuck
Second OUT_TEST KO
MV2 proximity missing
MV2 encoder missing
MV2 encoder Proximity missing
MV2 Proximity1, Proximity2
missing
MV2 encoder1 encoder2 missing
MV2 error congruence frequencies
MV2 encoder supply missing.
MV2 Encoder error
TWO-HAND concurrent failed
Not started
Waiting for restart
8540801 • 01/02/2017 • Rev.15
Redundancy check failed on input
Test output not connected to the right input
Stucked input
Photocell response time too low
The test signal on the photocell emitter is not seen on the receiver
The test signal is present on two different photcells
Wrong mat connection
The test signal on input is present on more than one OUT_TEST
The test signal is present on more than one input
The test signal on the input is not present on the OUT_TEST
Redundancy check failed on OUT_TEST
Proximity not present / Proxy not working
Encoder not present / Encoder unpowered
Device connected incorrectly
Both proxy must be connected
Both encoder must be connected
redundancy check failed on the measure.
Encoder not properly fed
Encoder signals with duty cycle and / or phase displacement not correct
Two-hands switch has to change state simultaneously
Start test failed
The input has manual reset and has not been restarted
Table 3
9