A200/A100 Hardware
3.3
Input Terminal (Parallel Input Port)
Terminal Positions
Input Circuit
Controller parallel input circuit
COM
( )
3 kΩ
Input
Rated operating
voltage: 5 V to 24 V DC
Maxmum additiv voltage: 30 V DC
Signal
Name
COM
COMMON
STA
START
COM
COMMON
ACK
ACKNOWLEDGE Data receiving complete signal
TYP
TYPE
IN1
IN1
IN2
IN2
IN3
IN3
IN4
IN4
IN5
IN5
IN6
IN6
IN7
IN7
IN8
IN8
+
+24 V DC
–
–24 V DC
FUNCTIONAL
EARTH
Example of connection with PLC used as NPN
External power supply
+
PLC output
COM
(±)
YO
IN1
COM(–)
Example of connection with PLC used as PNP
External power supply
+
PLC output
COM(+)
COM
YO
(±)
IN1
Input/Output Terminals (Input/Output Ports)
3.3
Input Terminal (Parallel Input Port)
Content
START common
Inspection start signal
COMMON, other than START input
Product type switched signal
Data input
Data input
IN1 to IN8
IN1 to IN8
Controller power supply
Controller power supply = 24 V DC
Functional ground
Micro imagechecker input
Micro imagechecker input
24 V DC
3 − 5