Precautions before installation

Make sure that dirt from the silicone-based seal material does not adhere within the toilet bowl.
Secure the space required for toilet installation and at the same time, check door opening/closing for possible interference.
Turn on the electricity and water supply for the product only after all other installation work is complete.
Do not damage the connection components on the water supply hose.
The water supply pressure ranges from 0.05 MPa(7.25PSI) <dynamic, 10 L/min(2.6gal/min) or more> - 0.75 MPa(108.75PSI)<static>.
Use the unit within the said pressure range. If the water supply pressure is low, toilet bowl cleaning may not be performed.
The temperature of the water supply should be within a range of 0 to 35°C(32-95°F). Make sure the temperature is within this range.
Working ambient temperature is within the range of 0 to 40°C(32-104°F). Make sure the temperature is within this range.
Prepare an outlet position in advance that conforms to the regulations in your country.
If there is a gap between the discharge pipe and floor, fill it with mold-resistant silicone-based seal material (Mediseal).
Doing otherwise may cause water to leak downstairs.
* Before installing appliances, be sure to completely wash out any dirt, sand, etc. from inside the water supply pipe.
* Because a water flow test is conducted on each product at the factory, water may remain inside the product.
This water does not indicate a problem with the product.
Make sure before installation that the water supply source and water drain pipe are in the specified positions according to the
diagram.
Water supply Rc 1/2
235mm±10mm
(9-2/8 )
140mm±10mm
(5-4/8 )
60mm±10mm
215mm±10mm
(2-3/8 )
(8-4/8 )
Water supply Rc 1/2
Tubo de descarga de PVC
The power plug (A-3) shape, power cord length, voltage, rated power consumption and maximum power consumption vary
depending on the version of the product. Check the appropriate type in the table below, and then wire and install the product
correctly.
Power plug blade shape
Power cord length
1.2m (3.94ft)
1.8m (5.91ft)
5.0m (16.40ft)
1.2m (3.94ft)
8
305mm±10mm
(12 )
Rated
Maximum
Voltage
power consumption
power consumption
120V
1297W
220V
835W
220-240V
835-845W
1445-1458W
Product Diagram (installation complete) image
[USA, Canada]
[Asia, Oceania, the Middle East, Korea, Macau]
1453W
1445W
140mm ± 10mm
60 mm±10mm
(2-3/8")
235mm±10mm
(9-2/8")
For floor water supply specification
468mm
(18-3/8")
290mm
(11-3/8")
43mm
(1-6/8")
820mm(toilet bowl end 810mm)
(32-2/8"(toilet bowl end 31-7/8"))
185mm
(7-2/8")
585mm
(23")
400mm
440mm
(15-6/8")
(17-3/8")
140mm ±10mm
(5-4/8")
For wall water supply specification
60 mm± 10mm
235mm± 10mm
For water supply from the floor
468mm
290mm
43mm
185mm
565mm
380mm
For water supply from the wall
215mm±10mm
(8-4/8")
138mm
(5-3/8")
701mm
(27-5/8")
667mm
1191mm
(26-2/8")
(46-7/8")
305mm
(12")
215mm± 10mm
138mm
820mm (toilet bowl end 810mm)
701mm
667mm
1171mm
305mm