Durr Dental VistaCam iX Proxi Installation And Operating Instructions Manual
Durr Dental VistaCam iX Proxi Installation And Operating Instructions Manual

Durr Dental VistaCam iX Proxi Installation And Operating Instructions Manual

Advertisement

Quick Links

VistaCam iX Proxi
EN
Installation and Operating Instructions
9000-618-254/30


Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VistaCam iX Proxi and is the answer not in the manual?

Questions and answers

Summary of Contents for Durr Dental VistaCam iX Proxi

  • Page 1 VistaCam iX Proxi Installation and Operating Instructions 9000-618-254/30 ...
  • Page 3: Table Of Contents

    Contents Cleaning and disinfection � � � � � � � � 11 7�1 Cleaning and disinfect the in- terchangeable head � � � � � � � � � 11 Important information 7�2 Cleaning the optical element � � � 11 About this document �...
  • Page 4: About This Document

    Important information About this document Other symbols These symbols are used in the document These installation and operating instructions and on or in the unit: form part of the unit� Note, e�g� specific instructions re- If the instructions and information in garding efficient and cost-effective these installation and operating in- use of the unit�...
  • Page 5: Safety

    Important information Safety General safety information When operating this device always ob- Dürr Dental has designed and constructed serve all guidelines, laws, and other rules this device so that when used properly and and regulations that are applicable at the for the intended purpose there is no danger site of operation�...
  • Page 6: Only Use Genuine Parts

    Important information Observe the EMC rules concerning med- Transport ical devices The original packaging provides optimum protection for the device during transport� For information on electromagnetic If required, original packaging for the unit compatibility (EMC), see the installa- can be ordered from Dürr Dental� tion and operating instructions for VistaCam iX (order number 9000- Dürr Dental does not accept any re-...
  • Page 7: Product Description

    Product description Overview Accessories The following articles are necessary to oper- ate the unit, depending on the actual appli- cation: Positioning holder (3 pieces) � � 2108-132-52 Poly disposable hygienic pro- tective covers, Proxi (500 pieces) � � � � � � � � � � � � � � 2108-010-60 Poly disposable hygienic pro- tective covers, Proxi (100 pieces) �...
  • Page 8: Technical Data

    Product description Technical data Operation Proxi interchangeable head Proxi interchangeable head Light source Wavelength Sharpness level Handpiece with Proxi interchangeable head Length Weight (without cable) Positioning holder Optical system Proxi interchangeable head Capture ring Handpiece The VistaCam iX handpiece with the Proxi interchangeable head creates a black and white image for detecting caries in the ap- proximal region�...
  • Page 9: Evaluation

    Product description Evaluation The black and white image shows struc- tures with varying translucency as different levels of brightness� The lower the translu- cency, the higher the reflection of the in- fra-red light and the brighter the structure� It is possible to make out to following struc- tures: –...
  • Page 10: Operation

    Operation Using the hygienic protective cover For information on the assembly, con- nection, and installation of the device, see the assembly and operating in- WARNING structions of the VistaCam iX hand- Danger of cross contamination piece (9000-618-176) and the instal- with failure to use or repeated lation and configuration manual of the use of a disposable hygienic VistaCam iX (document no�...
  • Page 11: Positioning The Unit Correctly

    Operation are no air bubbles between the optical obscure the optical element of the inter- window and the disposable hygienic pro- changeable head� tective cover� Hold the disposable hygienic protective cover firmly on the white edge and pull off the transparent plastic side in the direc- tion of the camera head�...
  • Page 12: Operating The Unit

    Operation Ensure that the relevant approximal area Operating the unit is located in the centre of the image sec- Reduce the penetration of external light� tion� Turn off or dim sources of external light If the structure underneath the enamel is (e�g�...
  • Page 13: Cleaning And Disinfection

    Operation Cleaning and Cleaning the optical element disinfection NOTICE Cleaning and disinfect the in- Damage of the optical element terchangeable head from incorrect cleaning Only use the cleaning set for Use the following cleaning and disinfectant VistaCam optical element� Disin- agents as disinfectant wipes: fectant residues soil the optical –...
  • Page 14 Operation With the interchangeable head removed, Preparing the positioning clean the surface of the image sensor us- holder ing the cleaning set for VistaCam Optik� The following instructions have been validat- ed by Dürr Dental in order to prepare the product for reuse� Reprocessing procedure: 1�...
  • Page 15 Operation Manually clean and disinfect using the Comply with all national and local guide- wet chemical process lines and standards regarding the sterili- sation of medical devices� When manually cleaning using the wet chemical process, use a VAH/ Storage DGHM listed disinfectant� Comply Store the product protected against con- with the reaction times stated in the tamination�...
  • Page 16: Technicians

    Troubleshooting Tips for operators and service technicians Any repairs above and beyond routine maintenance must only be carried out by suita- bly qualified personnel or by one of our service technicians� Problem Probable cause Solution Image is tool light in a The angle of the camera to Change the holding angle of specific region...
  • Page 20 Hersteller/Manufacturer: DÜRR DENTAL SE Höpfigheimer Str. 17 74321 Bietigheim-Bissingen Germany Fon: +49 7142 705-0 www.duerrdental.com info@duerrdental.com...