MAINTENANCE

Unplug unit before performing maintenance.
IMPORTANT NOTE: The following maintenance should be performed before each use:
• Check tightness of all hardware.
• Check operation and alignment of guard.
• Inspect Drum cores for cracks, damage or premature wear.
• Clean dirt and debris from motor air cooling slots.
BRUSH REPLACEMENT
NOTE: If motor fails to start as trigger is depressed
after extensive use, the Motor Brushes likely need
to be replaced.
1. Unplug Contour SCT from power supply.
2. Remove the Brush Caps (one each side)
with a small screw driver (FIG 5).
3. Pull Brush from socket (FIG 6).
4. Inspect Brush. NOTE: Brushes are
considered worn if less than 1/8" of
carbon is remaining).
5. Replace with new brush. NOTE: The carbon
contact goes in first and is keyed to the
rectangular socket.
6. Replace Brush Caps and tighten.
To order parts and supplies: 800.343.9353 >> eastwood.com
FIG. 5
FIG. 6
Brush Cap
Motor
Brush