Repairing and Replacing the Sensor
EN
•
You cannot reuse a strain gauge unit that has been removed.
Procedure for Repair and Replacement
•
See "Getting Ready" (page 5) before starting work.
1
Remove the crank set from the bicycle.
Refer to the documentation for the crank set regarding how to remove it.
2
Cut off the cable ties with the snips, and remove them.
3
Right sensor: Remove the junction cable guide.
•
Be careful that you do not lose the screws that you remove.
4
Remove the inner and outer chainrings from the crank set.
Refer to the documentation for the crank set regarding how to remove the chainrings.
54