Service contracts
Atlas Copco offers several types of service contracts, relieving you of all preventive maintenance
work. Consult your Atlas Copco Customer Centre.
General
When servicing, replace all removed O-rings and washers.
Intervals
The local Atlas Copco Customer Centre may overrule the maintenance schedule, especially the
service intervals, depending on the environmental and working conditions of the compressor.
The longer interval checks must also include the shorter interval checks.
Service interventions
Following actions have to be done on a regular basis:
Maintenance checklist
Period
Daily
Monthly
3-monthly (1)
Yearly or every
8000 hours (2)
Every 5 years or
40000 hours (2)
(1): More frequently when operating in a dusty atmosphere
(2): Whichever comes first
Apart from the above mentioned actions, the service interventions in the table below are
programmed in the memory of the Elektronikon™ controller. Each plan has a programmed time
interval at which all service actions belonging to that plan are to be carried out. When reaching
the interval, a message will appear on the screen indicating which service plans are to be carried
out. See section "Service menu" of the controller. After servicing, the intervals must be reset.
94
Operation
Check oil level.
Check readings on display.
Check air filter service indicator.
Check that condensate is discharged during operation.
Drain condensate.
Check that condensate is discharged when pressing the test button on top of the
electronic water drain.
On compressors with integrated dryer:
• Stop the compressor, close the air outlet valve and switch off the voltage.
• Remove any dirt from the condenser inlet with a vacuum cleaner.
• Next, clean with an air jet in the reverse direction of the normal flow. Use low
pressure air. Keep the compressed air nozzle more than 30 cm away from the
condenser to avoid damaging the of condenser fins.
• Remove dust from inside the dryer, e.g. with a vacuum cleaner.
Do not use water or solvents to clean the condenser.
Check coolers, clean if necessary.
Remove the air filter element and inspect. If necessary, clean using an air jet. Replace
damaged or heavily contaminated elements.
Check the filter element of the electric cabinet. Replace if necessary
Replace the wearing parts of the electronic water drain(s). A service kit is available.
Have the safety valve tested.
Replace all hoses and flexibles
Instruction book