Breakout Cable Specifications - Mitsubishi Electric MELSENSOR Vision Sensor VS20 Series User Manual

Fa sensor
Hide thumbs Also See for MELSENSOR Vision Sensor VS20 Series:
Table of Contents

Advertisement

Breakout cable specifications

Breakout cables provide power supply input, image acquisition trigger input, general-purpose input, high-speed output, and
RS-232 serial communication.
Breakout cables are not terminated.
2
2
3
3
4
4
10
10
1
1
11
11
5
5
9
9
12
12
6
8
8
6
7
7
P1: To a vision sensor
A: Power supply return pass
Pin Number
1
2
3
4
5
6
7
8
9
10
11
12
*1 () represents notations on In-Sight Explorer.
Precautions
Cut unused wires or protect them with insulating materials.
Be careful not to short-circuit with 24 VDC wires.
For RS-232 connection, use the power supply return path for the ground.
Cables are sold separately.
3 SPECIFICATIONS
22
3.3 I/O Specifications
P1
Signal name
*1
High-speed output 2 (Direct 2)
RS-232 Tx
RS-232 Rx
*1
High-speed output 3 (Direct 3)
General-purpose input 0 (Direct 0)
Input common
24 V DC
GND
Output common
Trigger
*1
High-speed output 0 (Direct 0)
*1
High-speed output 1 (Direct 1)
Wire color
Yellow
White/Yellow
Brown
White/Brown
*1
Violet
White/Violet
Red
Black
Green
Orange
Blue
Gray
A