Mitsubishi Electric MELSENSOR Vision Sensor VS20 Series User Manual page 51

Fa sensor
Hide thumbs Also See for MELSENSOR Vision Sensor VS20 Series:
Table of Contents

Advertisement

Connecting an I/O module (terminal block) to an input/output module
Operating procedure
1.
Decide how to connect the terminal block of the I/O module to the device.
2.
Using a screwdriver, loosen the applicable screw terminals.
3.
Connect I/O wires to I/O terminals of the terminal block.
4.
Connect the other end of the cable to the relevant I/O device.
5.
Using a screwdriver, tighten the screws and fix the lead wires on the I/O terminals of the terminal block. The maximum
tightening torque is 0.4 N⋅m.
Connecting an I/O module (RS232 OUT port) to a serial communication module
Only when using RS-232 communication, perform the following procedure.
Operating procedure
1.
Connect the RS-232 serial cable (DB9 connector) to the RS232 OUT port of the I/O module.
2.
Connect the other end of the RS-232 serial cable to the serial device.
3.
Tighten the connector screws to fix to the I/O module.
Connecting an I/O module cable to a vision sensor
Operating procedure
1.
Connect the M12 connector of the I/O module cable to the power, I/O, and RS-232 connector.
2.
Connect the DB15 connector of the I/O module cable to the SENSOR connector of the I/O module.
3.
Turn ON the power switch of the 24 V DC power supply connected to the I/O module.
6 SYSTEM CONSTRUCTION
6.10 Connection of an I/O Module
6
49