ALARM
CAUSE
Obstructed exhaust
Fume fan out of order
Obstructed connecting
nozzle
Faulty pressostat
AL 8 - FAILURE
Faulty electronic board
DEPRESS
Extreme chimney lenght
Advers whether
conditions
The fire door is not
correctly closed
Fire door microswitch
faulty or out of order
NICE - MIRIAM - CRISTAL - LEONORA - PRETTY - DIANA - KRISS - MARY
SOLUTION
The exhaust chimney is partially or totally obstructed.
Call en expert stove-repairer who executes a check
from the exhaust up to the chimney pot.
The pellet can burn also thanks to the chimney flue
depression without the aid of the fan. Have the
fume fan immediately replaced. It can be noxious to
health to let the stove running without fan.
Clean the connecting nozzle.
Replace the pressostat.
Replace the mother board.
Contact an expert stove repairer and check that the
exhaust chimney is in compliance with regulations:
see CHIMNEY FLUE page 51.
In case of strong wind there can be a negative
pressure to the chimney. Check and switch the stove
on again.
Close the fire door correctly and check if the gaskets
are broken.
Replace the fire door microswitch.
INTERVENTION