Allmatic BIOS1 Manual For Installation

Allmatic BIOS1 Manual For Installation

Programmable control board for sliding gates
Hide thumbs Also See for BIOS1:

Advertisement

Quick Links

CONTROL UNIT BIOS1
Programmable Control board for sliding gates
Manual for installation

Advertisement

loading
Need help?

Need help?

Do you have a question about the BIOS1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Allmatic BIOS1

  • Page 1 CONTROL UNIT BIOS1 Programmable Control board for sliding gates Manual for installation...
  • Page 2 1. Introduction The control unit BIOS1 is particularly indicated for the installation of 1 230 Vac motor with maximum power absorbed of 700W. The control unit equipped with a display that allows a precise regulation of the thrust and sensitivity. The control unit can memorize up to 8000 transmitters with the external memory, with the step by step, partial opening, open and close functions.
  • Page 3 POWER SUPPLY Power supply 230 Vac 50 Hz Connect the power supply cable between clamp Do not connect the card directly to the electric 1 and 2 of the control unit network. Put a device which can ensure the disconnection of each pole from the power supply of the control unit.
  • Page 4 4. Remote control learning 4. Remote control learning 4.1 Learning of one transmitter The 1st memorized button performs the STEP by STEP function (opening and closing of the gate), the 2 button performs the partial opening, the 3 button performs the OPEN function, 4 button performs the CLOSE function.
  • Page 5 5.2 Advanced settings of the stroke (parameter LsI LsI = P P P P ) Be sure that the limit switches are connected and correctly adjusted In this procedure is necessary to provide the positions of beginning of slowing down with a step by step command (SS). Unlock the gate and move it to the middle of the stroke Press and keep pressed the buttons UP[+] e MENU The gate moves in opening.
  • Page 6 6. Menu Ex. Base menu Entering the menu: To enter the base menu settings keep pressed the MENU button for at least one second To enter the advanced menu settings keep pressed the MENU button for at least five seconds Ex.
  • Page 7: Advanced Menu

    6.2 Advanced menu: SELECTABLE MENU DESCRIPTION VALUES DEFAULT UNITS min-max First coupling between Bluetooth device and control unit Electrical brake activation time EL EL F F F F 0 = disabled 0-100 x0.01 s 1 - 100= enabled Functioning of PHOTO1 moving from closed Sp Sp h h h h 0 = Check PHOTO1...
  • Page 8 6.3 Menu description: 6.3.1 Base settings menu tCL Auto reclosing time Active when the gate is in the completely open position, the gate automatically closes after tCL seconds. In this phase the display shows with the blinking dash, that during the last 10 seconds will be replaced by the count down. ttr Auto reclosing time after transit If in the opening phase or in the completely open position the beam of the photocells is obscured and freed, the gate automatically closes after ttr seconds when the completely open position is reached, In this phase the display shows...
  • Page 9 6.3.2 Advanced menu SI.d. Bluetooth Item of the menu needed to the first coupling between an Android device and the control unit. Refer to the Help of the Android application for the connection procedure. EL.F. Electrical brake Short reverse movement with reduced torque to reduce the inertia of the gate. The operation is performed at each stop of the movement except for fast movement after the intervention of a safety devices.
  • Page 10 de.a. Dead man During dead man functioning mode the gate moves only with a permanent command. The enabled commands are OPEN and CLOSE. SS and PED are disabled. During dead man functioning all the automatic movements are disabled, like short or total inversions. All safety devices are disabled except for STOP. se.r.
  • Page 11: Normal Functioning

    7.2 Normal functioning: Standby - Gate closed or after the switch on of the control unit Opening phase Closing phase Gate closed by user during opening Gate closed by user during closing Gate stopped by an external event (photocells, stop) Gate opened without automatic reclosing Gate opened in partial opening position without automatic reclosing Gate opened waiting for auto reclosing, last 10 seconds the dash will be replaced by the countdown...
  • Page 12 Italian law. ALLMATIC S.r.l 32020 Lentiai - Belluno – Italy Via dell-Artigiano, n° 1 – Z.A. Tel. 0437 751175 – 751163 r.a. Fax 0437 751065 http://www.allmatic.com - E-mail: info@allmatic.com 12 / 12 6-1622241 rev.6 04/12/2018...