Siemens SIMATIC C7-621 Manual page 57

As-i control system, first steps with step 7-mini and protool/lite
Hide thumbs Also See for SIMATIC C7-621:
Table of Contents

Advertisement

04/99
Network 4 : Operating mode display
A
DB1.DBX4.0
=
DB1.DBX6.0
=
M 21.0
FC2 : Eject conditions
Network 1 : Count
A
DB1.DBX1.0
A
DB1.DBX4.0
A
DB1.DBX0.1
FP
M30.0
CV
C1
L
C1
T
DB46.DBW2
AN
C1
A
DB1.DBX4.0
L
C#0
S
C1
L
DB46.DW2
L
DB46.DW0
>I
R
C1
Network 2 : Parcel sequence
A
DB1.DBX4.0
A
DB1.DBX0.0
FN
M30.1
L
S5T#10S
SE
T5
A
T5
A
DB1.DBX0.0
FP
M30.2
S
M21.1
Network 3 : Display: parcel detected
A
DB1.DBX4.0
A
DB1.DBX0.0
=
DB1.DBX6.2
=
M 21.3
Network 4 : Stop-monitoring
A
DB1.DBX4.0
A
DB1.DBX1.0
L
S5T#5S
SD
T3
A
T3
S
M21.2
Getting Started with C7-621-AS-i
// Belt ON
// Green lamp on casing
// Message flag
// Position switch
// Belt ON
// Inductive Bero
// Rising edge
// Count forward
// Transfer count to DB46.DBW2
// Count = 0
// Belt ON
// Write preset count
// Initialize counter
// If the value in DB46.DW2 is greater than
// the maximum value set, the counter
// is reset
// Belt_ON
// Opto_Bero: parcel
// Edge formation
// Parcel interval at least 10 seconds
// Pulse extension
// Parcel interval too small
// Opto_Bero: parcel
// Edge formation
// Fault in parcel sequence
// Belt ON
// Opto_Bero
// Lamp: parcel detected
// Message flag
// Belt ON
// Parcel at end of belt
// Monitoring time 5 seconds
// ON delay
// Fault in parcel stop
Program Example