Program Example
DB46:
OB 1:
Network 1 : Route process image of AS-i line to DB
OPN
DB1
L
PIW
256
T
DBW
L
PIW
258
T
DBW
Network 2 : Call system component belt control
CALL
FC 1
Network 3 : Call system component ejector
Call
FC 2
Network 4 : Write outputs
L
DBW
T
PQW
256
L
DBW
T
PQW
258
BE
FC1: Belt control
Network 1 : Initial position
AN
DB1.DBX0.0
AN
DB1.DBX1.0
A
DB1.DBX0.1
AN
M16.0
=
M15.0
Network 2 : Belt ON
A
DB1.DBX2.0
A
M 15.0
S
DB1.DBX4.0
Network 3 : Belt OFF
A
DB1.DBX2.3
O
M 16.0
R
DB1.DBX4.0
56
0
2
4
6
// Opto_Bero: no parcel
// Position switch: no parcel
// Ejector in initial position
// No fault
// Initial position
// Belt_ON switch on casing
// Initial position
// Conveyor belt ON
// Belt_OFF switch on casing
// Fault
// Output Belt_ON