Download Print this page

Advertisement

Quick Links

Instruction Leaflet K1121V10
Leat
Product luminaires comply with EN60598 and are suitable for use in normal interior conditions.
This luminaire has an ambient temperature range of -10 C to 25 C for the non-emergency version
For Emergency variants - This luminaire has an ambient temperature range of 5 C to 25 C, to ensure the batteries work correctly
1
Recessed - Bracket Installation
Aperture
Trim - 65.5mm wide
Trimless - 57.0mm wide
a)
Recommended Wooden Batten Spacing
44x44mm
Wooden
Battens
Drilling Direction
Cut aperture to required size.
Using the flat bracket (sold separately) as a drilling template, drill 4 x holes
5mm dia, through pilot holes. See 'Bracket Orientation'.
Counter sink the drilled holes so c/sk screws (supplied) sit flush with
the plasterboard.
c)
o
o
Trimless - Run Length + 10.5mm
For Plasterboard Support
240mm MAX
Plasterboard
160mm MIN
Drilling Direction
Fold flat bracket over and fix spring clip.
Fit main bracket into slider brackets. Ensure that
dimension 'a' from bottom of plasterboard to the inside
face of main face is adhered to. Tighten slider
bracket screws to hold main bracket in place.
December 2019
o
o
Fixing crs
Aperture
Trim - Run Length + 8.0mm
Bracket Orientation
When using the flat bracket for the drill hole locations make sure the metalwork is
in the correct orientation.
The image on the left shows the orientation for the trimless variant and the image on
the right shows the orientation for the trimmed version.
Fixing Centres (per fitting)
700mm
1.0m
1.5m
1200mm
2.0m
1700mm
2700mm + centre fixing
3.0m
b)
Secure each slider to
plasterboard using M5
c/sk screws supplied
IMPORTANT: Once brackets
are fully installed. Plaster surface
before installing the Leat.
Dim 'a'
Trimmed
79.0mm
Trimless
76.0mm

Advertisement

loading

Summary of Contents for Eaton K1121V10

  • Page 1 Instruction Leaflet K1121V10 December 2019 Leat Product luminaires comply with EN60598 and are suitable for use in normal interior conditions.  This luminaire has an ambient temperature range of -10 C to 25 C for the non-emergency version  For Emergency variants - This luminaire has an ambient temperature range of 5 C to 25 C, to ensure the batteries work correctly ...
  • Page 2 Instruction Manual - K1121V10 Leat December 2019 Surface Bracket Installation IMPORTANT DO NOT REMOVE ENDCAPS b) Using a screwdriver, gently disengage the geartray using the slotted tabs a) Remove diffuser using the suction cup (supplied) positioned at the centre of the diffuser.
  • Page 3 Instruction Manual - K1121V10 Leat December 2019 Geartray Clamp Continuous Installation a) Follow procedures ‘a’ to ‘c’ as per Cable Entry ‘Surface Bracket Installation’. Start of Run b) Install desired fixing method (recessed, surface or suspended) and wire. c) Fix both leat housings using the...
  • Page 4 Instruction Manual - K1121V10 Leat December 2019 Leat Corner (500mm) - Sold Seperatley A (External) Follow steps ‘a, b, c, d’ and ‘f’ under  0.143m 0.143m ‘Continuous Installation’ on page 3. After step ‘f’ cut the diffuser, using the ...