Page 2
ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to...
MEDC recommends that all cables and cores should be correctly identified. Please refer to the wiring diagram in this manual (or separate diagram provided with the unit). LED BEacon LD15 TM334 Issue A October 2018 www.eaton.com...
Ensure the cover seal is correctly seated in its groove during re-assembly. There should be a maximum gap of 0.2mm between the faces of the cover and enclosure to ensure O-ring compression. LED BEacon LD15 TM334 Issue A October 2018 www.eaton.com...
3 way DIL switch Steady mounted on the underside of the electronics assembly. Double flash The switch settings for the various modes of operation are as follows: LED BEacon LD15 TM334 Issue A October 2018 www.eaton.com...
MEDC. All parts of the unit are replaceable. If you acquired a significant quantity of units, then it is recommended that spares are also made available. Please discuss your requirements with the Technical Sales Engineers at MEDC. LED BEacon LD15 TM334 Issue A October 2018 www.eaton.com...
The IECEx certificate and product label carry the IECEx 8.0 Functional safety equipment protection level marking. The LD15 Beacon has been designed for use in potentially explosive atmospheres and harsh environmental conditions. The glass reinforced polyester enclosures are Where Gb signifies suitability for use in a Zone 1 surface suitable for use offshore or onshore, where light weight industries area in the presence of gas.
See report R56A31253B Systematic safety integrity compliance Systematic Capability SC2 (R56A31253B) (SC1, SC2, SC3, SC4) Hardware safety Limited to: SIL 1 (1oo1) & SIL 2 (1oo2) due to integrity achieved SFF value. LED BEacon LD15 TM334 Issue A October 2018 www.eaton.com...
LD15 LED Beacon Verdict conducted a Failure Modes Effect and Diagnostic Clauses Single Mode Redundant Mode Analysis (FMEDA) of the LD15 LED Beacon against the 2/7.4.2 and 2/7.4.4 (1oo1) (1oo2) requirements of IEC 61508-2 using a Proof Test Interval Architectural...
SIL 2 can be achieved. The installation must be such as to ensure sufficient protection against common cause failures and independence from cascading failures. LED BEacon LD15 TM334 Issue A October 2018 www.eaton.com...
Page 13
Avaliação da segurança funcional – LD15 DC ........
Também podem ser aplicáveis outros requisitos rosca M8. nacionais e/ou locais. VII. A terminação dos cabos deve estar em conformidade com as especificações referentes à aplicação em questão. A MEDC recomenda que LED BEacon LD15 TM334 Issue A October 2018 www.eaton.com...
Assegure-se de que a vedação da tampa tenha sido corretamente assentada em sua ranhura durante a remontagem. Deve existir um espaço máximo de 0,2 mm entre as superfícies do gabinete e da tampa, para garantir a compressão do O-ring. LED BEacon LD15 TM334 Issue A October 2018 www.eaton.com...
Luz fixa mediante um interruptor DIL de 3 vias presente na parte Sinal luminoso duplo inferior do conjunto eletrônico. As configurações do interruptor para os diferentes modos de funcionamento são os seguintes: LED BEacon LD15 TM334 Issue A October 2018 www.eaton.com...
(PFPE), como o Krytox GPL203 da DuPont ou Perfluorolube 22/6 da Performance Fluids Ltd., a fim de evitar danos Se a unidade apresentar uma falha, poderá ser reparada ao O-ring. pela MEDC. Todas as peças da unidade são substituíveis. LED BEacon LD15 TM334 Issue A October 2018 www.eaton.com...
8.0 Segurança funcional Onde Db significa adequado para uso em uma área industrial de superfície de Zona 21 na presença de poeira. O Sinalizador LD15 foi projetado para uso em ambientes potencialmente explosivos e condições ambientais Unidades ATEX adversas. As carcaças de poliéster reforçado com fibra de vidro são adequadas a utilização marítima ou terrestre,...
2/7.4.2 e 2/7.4.4 Modo simples Modo redundante diagnóstico e efeitos de modos de falha (FMEDA) no (1oo1) (1oo2) Sinalizador LD15 LED em relação aos requisitos da norma Limitações HFT=0 HFT=1 Tipo B IEC 61508-2 usando um intervalo de teste de prova de arquitetônicas...
Conformidade de integridade de segurança sistemática Capacidade sistemática (SC1, SC2, SC3, SC4) Integridade de Limitado a: SIL 1 (1oo1) e SIL 2 (1oo2) devido ao segurança alcançada valor de SFF. pelo hardware LED BEacon LD15 TM334 Issue A October 2018 www.eaton.com...
SIL 2 podem ser alcançadas. A instalação deve ser tal que garanta proteção suficiente contra falhas de causas comuns e independência de falhas em cascata. LED BEacon LD15 TM334 Issue A October 2018 www.eaton.com...
Page 22
Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to Trademarks (especially Eaton, Moeller, and Cutler-Hammer). The Terms and Conditions of Eaton apply, as EaoNn referenced on Eaton Internet pages and Eaton order confirmations.