• Never insert any objects or limbs into the device. • Do not cover or transport the device during operation. • Do not sit on the device. condenser dryer DH 25 S / DH 65 S...
Page 3
Warning Intended use comprises: Risk of suffocation! • drying and dehumidifying: Do not leave the packaging lying around. Children may use it as a dangerous toy. condenser dryer DH 25 S / DH 65 S...
15 °C. The device has a control panel for operating and controlling the functions. Because of the heat radiation generated during operation, the room temperature may rise slightly. condenser dryer DH 25 S / DH 65 S...
Use cable bridges. • Make sure that extension cables are completely unrolled. • When positioning the device, keep a sufficient distance to heat sources. condenser dryer DH 25 S / DH 65 S...
Page 6
3. Guide the other hose end to a suitable drain or sufficiently dimensioned collection container. Please note that the hose must not be kinked. condenser dryer DH 25 S / DH 65 S...
For increasing the desired relative button humidity level (30 % to 80 %) 16 Decrease value For reducing the desired relative button humidity level (30 % to 80 %) 17 POWER button Switching the device on and off condenser dryer DH 25 S / DH 65 S...
Page 8
Memory function In case of brief power failures the device memorizes the programmed nominal value for humidity. The pre-programmed start and stop times for automatic operation are not saved. condenser dryer DH 25 S / DH 65 S...
(see chapter Maintenance). If the inside of the device is dirty, have it cleaned by a specialist company for cooling and air- conditioning or by Trotec. condenser dryer DH 25 S / DH 65 S...
Page 10
T3 > 35 °C and relative humidity <75 % Hi t The temperature or humidity sensors are Only restart the device when the temperature is <30 °C. malfunctioning T3 > 32 °C and relative humidity ≥78 % condenser dryer DH 25 S / DH 65 S...
Page 11
LoPS The LPS contact is open Have the device checked by a specialist company for cooling and air- (see wiring diagram) conditioning, and have the measuring equipment exchanged if necessary. condenser dryer DH 25 S / DH 65 S...
Page 13
4. Reinsert the air filter into the device. repaired by specialist companies for cooling and air- conditioning or by Trotec. condenser dryer DH 25 S / DH 65 S...
Minimum distance to walls or other objects: A: top: 50 cm 50 cm B: rear: 50 cm 50 cm C: side: 50 cm 50 cm D: front: 50 cm 50 cm Length x width x height 580 x 343 x 457 mm 667 x 517 x 553 mm Weight 34 kg 53 kg condenser dryer DH 25 S / DH 65 S...
Page 15
Wiring diagram DH 25 S condenser dryer DH 25 S / DH 65 S...
Page 16
Wiring diagram DH 65 S condenser dryer DH 25 S / DH 65 S...
Page 17
L=1 Trotec Suction grid Capillary and filter Tamp. dx evap.dwl Trotec air filter Motor fan 10W 230V50/60Hz Tamp. sx evap.dwl Handle Fan motor ring Ø 238 Cover Fan Ø 230 condenser dryer DH 25 S / DH 65 S...
Page 18
25 Electric valve Ø 3 mm 36 Tamp.dx Evaporator 12 Suction grid 26 Compressor PA160 R410A 40 Tamp.sx Evaporator 13 Air filter 27 Omega support for wheels 14 Handle 28 Motor fan 100W 230V50/60Hz condenser dryer DH 25 S / DH 65 S...
DH 25 S Product model / Product: DH 65 S Place and date of issue: Heinsberg, 01.06.2015 condenser dryer Product type: Year of manufacture as of: 2019 Detlef von der Lieck, Managing Director condenser dryer DH 25 S / DH 65 S...