Trotec 3510010021 Operating Manual

Fog and flue gas simulator

Advertisement

Quick Links

FS 200
EN
OPERATING MANUAL
FOG AND FLUE GAS
SIMULATOR

Advertisement

Table of Contents
loading

Summary of Contents for Trotec 3510010021

  • Page 1 FS 200 OPERATING MANUAL FOG AND FLUE GAS SIMULATOR...
  • Page 2: Table Of Contents

    Information about the device.......... 4 Transport and storage............ 6 Operation ................ 6 FS 200 Available accessories ............ 9 Errors and faults.............. 9 https://hub.trotec.com/?id=43769 Maintenance and repair ............ 10 Safety Disposal ................ 11 Read this manual carefully before starting or using the device. Always store the manual in the immediate vicinity Notes regarding the operating manual of the device or its site of use.
  • Page 3 To use the device for its intended use, only use accessories and very hot! Always wear protective gloves when working spare parts which have been approved by Trotec. with the flue gas chamber. Only use the device for generating fog. Only use the device within the framework of the technical data.
  • Page 4: Information About The Device

    Do not operate the device without fog fluid! Without fog fluid, the pump can be damaged. Note Only use Fluitect fog fluid from Trotec. Other fog fluids can damage the device. Note To prevent damages to the device, do not expose it to extreme temperatures, extreme humidity or moisture.
  • Page 5 230 V / 50 Hz Type of protection IP 54 Air flow rate Approx. 68 l/s (approx. 245 m Designation Meaning Approved fluid Trotec FluiTect fog concentrate On/off switch For switching the device on Fluid quantity 5 l and off Fluid consumption at 100 ml/min Heating-up phase...
  • Page 6: Transport And Storage

    1. Remove the safety bolt (20). Transport and storage 2. Fold the holder's stabiliser (21) in until it is located at the same height as the lower holder (22). Note 3. Fold down the upper holder (23) until it abuts the housing. If you store or transport the device improperly, the device may be damaged.
  • Page 7 • minimum distance of 2 m to combustible or heat-sensitive Connecting the canister objects • sufficient supply of fresh air Information regarding the operation with emergency power units • The applied emergency power generators must be asynchronous, feature a nominal capacity of min. 4 kVA (230 V) and be checked for proper functioning.
  • Page 8 ð The heating-up phase of the device starts. ducts) often demand the application of coloured smoke. For 7. Wait for approx. 7 minutes until the heating-up phase is ® these applications please use the TROTEC flue gas chamber completed. ® combined with the coloured TROTEC smoke cartridges.
  • Page 9: Available Accessories

    Your device still does not operate correctly after these checks? Please contact the Trotec customer service. 1. Use the controller (14) to switch the pump off again. The pump (11) indicator must no longer be illuminated. 2. Set the turbine controller (13) to 12 o'clock position to let the turbine run at medium speed.
  • Page 10: Maintenance And Repair

    Cleaning filter mats Maintenance and repair Both filter mats must be cleaned on a regular basis. In case of Activities required before starting maintenance excessive contamination or damage the filter mats must be • Do not touch the mains plug with wet or damp hands. replaced.
  • Page 11: Disposal

    For further return options provided by us please refer to our website https://de.trotec.com/shop/. The separate collection of waste electrical and electronic equipment aims to enable the re-use, recycling and other forms...
  • Page 12 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...