3 Installation and Commissioning
Step
6. The remaining steps in commissioning involve
downloading the configuration data and user
programs.
Requirement:
You have configured the CP in a STEP 7
project with HW Config and NetPro for the
services you want to use.
7. User diagnostics for commissioning and to
analyze problems.
8. Optional when using with PROFINET CBA:
Download PROFINET CBA component
Caution
Remember the following points regarding the power supply during installation:
S
When using the CP in the central rack or in a universal rack operating as the
central unit, the following applies:
The CP 443-1 Advanced should not be inserted or removed while the power
supply is on. If you remove the CP when the power supply is on, the CPU
changes to STOP and indicates "I/O error" (in contrast to previous modules!).
After inserting the module with power applied, it is essential to turn the power
supply off and on again.
S
When using the CP in a universal rack operating as an expansion unit, the
following applies:
Before removing or inserting the CP, turn off the power supply of the expansion
unit. The CPU can then continue to operate and recognizes the "rack return
signal" when the power supply of the expansion unit is turned on again.
B4A−16
Explanation / Meaning
You can connect the PG when configuring the CP
as follows:
S
via MPI
S
via Industrial Ethernet
For more detailed information is, please refer to
/Part A/:
− First addressing (node initialization)
− Downloading the defined configuration
The PG/PC requires a LAN attachment, for
example via a CP 1613 or CP 1411 and must have
the necessary software (for example the S7 1613
package or SOFTNET IE). The TCP/IP protocol or
ISO protocol must be installed. The protocol used
must then be applied to the S7ONLINE access
point.
The following options are available:
S
Hardware diagnostics and troubleshooting with
STEP 7
S
Communication diagnostics with NCM S7
Diagnostics
S
Standard information using HW Config
If the S7 station in which the CP is operated is used
as a PROFINET CBA component, the
interconnections are downloaded using SIMATIC
iMap; for more detailed information, refer to the
topic "Using the CP with PROFINET CBA".
CP 443-1 Advanced for Industrial Ethernet / Manual Part B4A
Release 01/2007
C79000-G8976-C193-06