Occurs in case of water
AL I
T detection probe fault,
WATER
displaying T H
The shutdown procedure
PROBE S3
is activated.
In the work stage the boiler
AL M
detects the fire door and/or
DOOR
ash door opening.
OPEN
The system is stopped.
Occurs when the water
AL H
temperature has exceeded
HOT
the fixed limits.
WATER S3
The system is stopped.
Occurs on relighting the
AWAITING
boiler immediately after
COOL
having shut it down.
AIRFLOW
Occurs when the air flow
METER
meter is disconnected.
FAILURE
Occurs when the water
FROST RISK
temperature falls below a
certain value.
Occurs when the boiler has
SERVICE
exceeded 1800 hours of
DUE
operation or 2000 Kg pellet
since the previous servicing.

12. REQUESTING ASSISTANCE AND REPLACEMENT PARTS

To request assistance and/or replacement parts, contact the dealer, area importer or the
nearest Authorised Service Centre, clearly specifying the following:
▪ boiler model,
▪ serial number,
▪ date of purchase,
▪ list of replacement parts,
▪ details of faults or malfunctioning.
All operations on components must be carried out by authorised and/or
qualified personnel.
Make sure all electrical connections are disconnected and that the boiler is
cold before any work on it.
Only use original replacement parts.

13. ANNEXES

13.1 WIRING DIAGRAM

Before installing the boiler in the home, check the type of heating system; if
there are several zones, a special electronic controller for multi-zone circuits,
available as an optional, must be installed. This is to prevent overheating
of the unit due to possible simultaneous closing of the zone valves and
consequent stopping of hot water delivery flow.
80
O = 0 °C.
2
Occurs when the
temperature probe in the
heating chamber detects a
value above 92°C.
Reset attempt in shutdown
stage with boiler hot in
cooling stage.
The controller does not detect
the amount of combustion air
and does not shut down the
boiler; it only excludes the air
flow meter functions.
Extraordinary maintenance
notice.
cod. 48427B011_01/18_Hardware / M.Software 6.0
EASYFIRE 29 - 35 - 39
Faulty probe
The probe is
disconnected from the
board.
The fire door is not closed.
The ash door is not closed.
Defective switch.
The boiler controller
detects the water
temperature below 6°C
and displays a message.
Reinstatement operations must
be carried out by a service centre.
Check hermetic closing of the fire
door and/or ash door.
Other reinstatement operations
must be carried out by a
service centre.
Check the cause of the problem,
restoring the temperature by
bringing it to the normal operating
value.
Alarm reset is possible only after
shutdown.
Reinstatement operations
must be carried out by a
service centre.
The pump starts in order to
move the water inside the
heating circuit.
Monitor the water temperature
so that it does not fall below
0°C.
Cleaning - extraordinary
maintenance and reinstatement
operations must be carried out by
an authorised service centre.