14
model no. 299-3117-6 | contact us 1-800-689-9928
BREAK-IN OF THE PUMP
PUMP SHIPPED WITHOUT OIL. Fill pump to correct mark and check often. SAE-30
non-detergent oil is recommended for general use.
•
Check the level of oil in the pump with the sight glass. The
pump oil level must be between A and B (see Fig. 5). Do not overfill or
underfill.
•
Turn the pressure switch to the OFF position (C).
•
Open the petcock (F).
•
Plug in the power cord.
•
Turn the pressure switch to the ON position (D). The compressor will start.
Allow the compressor to run for 30 minutes, to break in the internal parts.
•
NOTE: After about 30 minutes, If the unit does not operate properly, SHUT
DOWN IMMEDIATELY, and contact Product Service.
•
After about 30 minutes, turn the pressure switch to the OFF position.
•
Close the petcock (E).
•
Turn the pressure switch to the ON position. The compressor will start and fill
the tank to the kick-out pressure and stop.
•
NOTE: As compressed air is used, the pressure switch will restart
the motor automatically.
Fig.5
headline bars
headline bars
continuation tabs
continuation tabs
notes
notes
warnings
warnings
D
C
A = Full
B = Add
F
OPEN
E
CLOSED