Setting Up System Options
•
9600 baud
•
No parity
•
8 data bits
•
1 stop bit
•
Hardware flow control to OFF
The default port configuration for the SCU craft port is CRAFT. Ports 2 and 3 must be configured
for CRAFT before the craft interface may be accessed via these ports.
5
At the maintenance terminal, press
C
ONNECTING A
P
ORT
1
Locate the D3RCAM in the remote cabinet. The D3RCAM craft port is located on the front of the D3RCAM.
2
Select the cable for use between the craft port and the maintenance terminal with a DB-9 (male) connector at
one end and a maintenance terminal connector at the other end.
3
Connect one end of the interface cable to the maintenance terminal and the other end to the D3RCAM craft
port as shown in
4
Start a terminal emulation program such as Procomm that emulates a VT100 terminal.
20
Figure 11. Connecting a Maintenance Terminal to the SCU
. The Enter User Name field appears.
ENTER
M
T
AINTENANCE
Figure
12.
August 30, 2002
Maintenance
Serial
COM port
LEC
Craft port
ERMINAL TO THE
LTPS-UM-8013-03
terminal
Interface cable
D3RCAM C
RAFT
D3LX CO and RMT Modules