Protection Switching; D3Lx Front-Panel Description And Status Leds - ADC Soneplex D3LXC-FCA100 User Manual

Adc soneplex ds3 loop extender (d3lx) co module and rmt modules user manual
Table of Contents

Advertisement

Front-Panel Description
Name
Function
LEDs
The LEDs can report the following conditions:
Activity
STATUS
Off
On (solid)
On (solid)
On (solid)
FAR END
Off
On (solid)
DS3 STATUS Off
On (solid)
On (flashing) Green
On (solid)
On (flashing) Red
DS3 ONLINE Off
On (solid)
OPT
Off
On (solid)
On (solid)
APS
Off
On (solid)
On (solid)
ENABLE
Pressed with APS
pushbutton
Pressed with RESET
LMPTST/APS
Pressed
pushbutton
Pressed with ENABLE
RESET
Pressed
pushbutton
Pressed with ENABLE
Retaining latch
Secures the D3LX when it is firmly seated in the backplane of the chassis and the latch is in the upright position
P
S
ROTECTION
WITCHING
The D3LX system may be configured for either protected or non-protected mode. For protected mode, two
modules are installed: working and protect. The working module carries the signal, while the protect module is in
standby. Each working module uses 1 group, physically occupying 2 slots. Each protected module occupies an
additional 2 slots; there are four slots required for each D3LX system.
In protected mode, the offline module is switched into service whenever the D3LX determines that a service fault
has occurred in the online module.
4
Table 1. D3LX Front-Panel Description and Status LEDs
Color
Status
Not lit
Blown fuse
Green
Normal operation.
Yellow
Module initializing or performing self test diagnostics or LED test.
Red
Module fault detected.
Not lit
Remote alarms inactive (no alarm).
Yellow
Remote alarm on D3LX CO.
Not lit
Unequipped.
Green
DS3 active.
DS3 in loopback, output AIS.
Red
DS3 fault (LOS).
DS3 in loopback, output AIS.
Not lit
DS3 offline.
Green
DS3 active.
Not lit
Optical link active (normal operation).
Yellow
BER fault.
Red
Optical link failure (OOF)
Not lit
No protection switching (normal operation).
Yellow
Force manual protection enabled.
Red
Protection switching limit.
In a protected system, the active DS3 are force switched to that module.
Note: The ENABLE pushbutton is pressed first and released last.
Cold start reset (service affecting).
Note: The ENABLE pushbutton is pressed first and released last.
Lights front-panel LEDs yellow, except for STATUS and DS3 STATUS which light red.
In a protected system, the active DS3 are force switched to that module.
Note: The ENABLE pushbutton is pressed first and released last.
Warm start reset (non-service affecting).
Cold start reset (service affecting).
Note: The ENABLE pushbutton is pressed first and released last.