7.3. Programming Current Control:
DEC

Current Control

page 4
>User Setup
:
Current
:
On [1500us] : 1500us
On Method
: On
Stop[1100us] : 1100us
Parameter
Current
On [XXXXus]
On Method
Stop
Connecting the components:
Battery (IN)
Telemetry socket (T)
connect to telemetry so-
cket of the receiver
Electronic speed control
(CO)
Signal Input (CI)
ESC input from receiver
Use the three-core lead to connect the
socket T on the receiver. Connect the electronic speed controller to the socket CO.
Use a three-core lead to connect the
ver socket to which the electronic speed controller would usually be connected.
Current control can be activated and disabled from the transmitter: for this function you need one vacant swit-
ched channel. Connect the associated receiver output to the socket CS on the General Engine-Module using
a three-core lead.
13
INC
In this display you can determine and limit the maximum current drawn
by the model's power system.
40 A
If the model's current drain is above the permitted peak current for the
General Engine-Module, it is essential to use this function to prevent
damage to the module or a break in the power supply, as this would
be likely to cause the model to crash (see also Point 3: connecting the
sensors).
Description
Maximum current
Current control activated
Current control enabled, is the current consumption
above the CURRENT value, the ESC goes to STOP po-
sition until to the current consumption drops again
Current control disabled, IN signal CI is outputted as
CO without modifi cation
ESC position when current consumption above the
CURRENT value
Balancer connector LiXX
for single cell monitoring when using a LiXX-
telemetry socket T on the General Engine-Module to the telemetry
battery
socket CI on the General Engine-Module to the recei-
33610 General Engine-Module - Graupner HoTT 2.4
Setup
0 - 60 A
500 - 2500 us
ON / OFF
500 - 2500 us
to drive motor (OUT)
Note: the permitted maximum
current for the lower JR so-
ckets is 5 A! This socket may
only be used if the model's
power system never exceeds
this value. If you ignore this,
the sensor circuit board could
be damaged!
Current control switch (CS)
ON/OFF per switching chan-
nel