Toshiba V Series Installation And Wiring Manual page 22

Integrated controller information and control network module
Hide thumbs Also See for V Series:
Table of Contents

Advertisement

Chapter 2 TC-net 100 Cabling (Optical Fiber Cable)
2
10
• Clamp the cables so that the connectors will be free of the cable weight and the force
of cable bends.
• After wiring, check that the cables satisfy the allowable bending radius requirements
specified in Table 2-1 Allowable Cable Bending Radiuses on page 10. If any cable is
found not satisfying the requirements, install it again so its bending radius is equal to,
or greater than, the figures specified in the table.
Table 2-1 Allowable Cable Bending Radiuses
Cable
Optical fiber cable
Optical fiber cord
Allowable Bending Radius (mm)
Outer Size (mm)
Clamped
17.0
170
5.0
50
Installed
20 times cable
OD or more
50
TC-net 100 Installation and Wiring Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tc-net 100

Table of Contents