Configure Syslog And Snmp Notifications; Make Host Connections - Hitachi VSP F370 System Installation

(without svp)
Hide thumbs Also See for VSP F370:
Table of Contents

Advertisement

Next steps
(Optional) Configure syslog and SNMP notifications.

Configure syslog and SNMP notifications

Before you begin
Make sure the storage system is connected to your production network.
Procedure
1. In the navigation tree of the maintenance utility, under Administration, click Alert
Notifications. Then click Set Up in the Alert Notifications pane on the right.
2. To configure the storage system to send notifications in syslog format, complete the
settings in the Syslog tab. Then open a firewall port on your network for
transferring syslogs.
3. To configure the storage system to send notifications as SNMP traps, complete the
settings in the SNMP tab.
4. Click Apply, and then click OK.
Step 7: Make host connections
Note: Although a tab is provided for configuring email notifications, we
recommend that you set up email notifications using Hi-Track Remote
Monitoring system.
Installing your storage system
Storage system installation (without SVP)
Configure syslog and SNMP notifications
27