Country and Plug Specification
United Kingdom:
• BS1363 male plug with fuse
• Harmonized cord
Australia:
• AS3112-1981 male plug
Danger:
Using power cords with a proper grounding path
Use only power cords that have a grounding path. Without a proper ground, a person who
touches the switch is in danger of receiving an electrical shock. Lack of a grounding path to the
switch can result in excessive emissions. For a translation of this statement, see
safety messages
DC power supply
Installing a DC power supply
Important:
Avaya does not support installing a combination of AC-input and DC-input power supplies in the
same chassis.
The Avaya Virtual Services Platform 8000 Series supports two field-replaceable 800 W power
supplies. One comes with the switch and you can install a second power supply to provide
redundancy and load sharing.
There are two power supply slots (PSU1 on top and PSU2 on the bottom).
• If you only have one power supply, you can install it in either PSU1 or PSU2.
• If you install a second power supply, neither one acts as a primary power supply. The two
power supplies load share equally.
Before you begin
• If you are replacing an installed power supply, see
• Remove the DC power supply wiring assembly before installing or removing the power supply.
November 2016
on page 88.
Installing the Avaya VSP 8000 Series
Comments on this document? infodev@avaya.com
Specifications
• 240VAC
• 50 Hz
• Single phase
• 240VAC
• 50 Hz
• Single phase
Removing a power supply
DC power supply
Typical Plug
Translations of
on page 79.
75