Pepperl+Fuchs LAL-SRW series Manual page 14

Warning device
Hide thumbs Also See for LAL-SRW series:
Table of Contents

Advertisement

Available languages

Available languages

WARNING DEVICE LAL-SRW
Installation
3.1.1
EN
12 - EN
Mounting the NVF-104/34-PF Overflow Sensor
Usually, the sensor is mounted with the lower edge a few centimeters above the
normal liquid level (water zero line) in a position so close to the water zero line that
the switching point is surrounded by liquid when an overflow occurs. This occurs
if the coalescence filter is dirty,
if the automatic closure device is blocked, or
if another situation causes the oily liquid to overflow or become contaminated.
The switching point is at the same level as the 5 mm hole on the side of the
sensor.
1
A
B
C
Figure 3.2
Mounting the overflow sensor
1
Overflow sensor NVF-104/34-PF
A
Air
B
Oil
C
Water
L
Water zero line
S
Sensor switching point
X
Alarm limit (maximum liquid level)
S
L

Advertisement

Table of Contents
loading

Table of Contents