5. Upgrading the firmware

The firmware package is downloaded from Grundfos Technical
Information found on Insite under "Toolbox".
1. Go to Grundfos Insite and select "Toolbox".
2. Select "GTI - Grundfos Technical information".
3. Select "Service Support Tools".
4. Select the CUE firmware.
5. Copy the files to a USB stick.

6. Additional information

6.1 Special service tools

A
Pos.
Description
A
Torque screwdriver
Digital multimeter, type RMS, CAT III / 1000 V, (KAT III/1200 V for 400/690 V), with
B
diode testing function
C
Clip-on amperemeter

6.2 Tightening torques

Tightening torques for terminals
Tightening torque [Nm]
Enclosure
Mains
91, 92, 93
A2
1.8
A3
1.8
A5
1.8
B1
1.8
B2
4.5
B3
1.8
B4
4.5
C1
10
1)
2)
C2
14
/ 24
C3
10
1)
2)
C4
14
/ 24
1)
Conductor cross-section ≤ 95 mm
2)
Conductor cross-section ≥ 95 mm
26
Motor
Earth
Relay
96, 97, 98
95, 99
01-06
1.8
3
0.6
1.8
3
0.6
1.8
3
0.6
1.8
3
0.6
4.5
3
0.6
1.8
3
0.6
4.5
3
0.6
10
3
0.6
1)
2)
3
0.6
14
/ 24
10
3
0.6
1)
2)
3
0.6
14
/ 24
2
.
2
.
B
Further information
C
Part number
0.5 - 4.0 Nm
SV0435