No Front Status Led Condition - Jaco ULTRALITE 500 Series Manual

Table of Contents

Advertisement

If the connection inside the fuse is not broken, the issue is with the JACO Power Inverter
assembly and you will need to contact JACO Customer Support to address replacement.
Please see page 3 for locating the correct information that will be needed to start the
replacement process.
If one or both fuses show a break, they will need to be replaced. Contact JACO Customer
Support for details.
– "My power system is providing power to the LCD and

No Front Status LED Condition

PC but I do not have any front status LED indication showing".
1 – Check the Status LED Cable making sure that it is connected properly as shown. You will
need to remove the protective cover inside the Cart top assembly. First remove the Cart work
surface and then, using an 11/32" nut driver, remove the protective cover shown below.
If not seated correctly, position and reconnect. If the front status is still not working, check
the other end of the cable connection as shown below. You may need to remove the internal
PC to get access to the power inverter. Follow the cable from the front status enclosure and
make sure that it is seated properly. Disconnect and reconnect if needed.
19