Error code
01-03
Command syntax error or FS selection error (due to specifying an invalid FS)
04
Value error
91
MU switching process failure
98
Command format error
99
Timeout error (ACK[CR][LF] not returned within time limit)
11-2-3. Connection Status Request Command (Status)
Command statement
Status,10RU,Get,0[CR][LF]
Normal Response
Return message (TCP): ACK[CR][LF]
A status message (UDP) shown below follows:
Connection status message (UDP)
Status,10RU ,RPT,<Status>,< USF-1043FS IP address:port number>,<FS
number>[CR][LF]
(Ex.) Status, 10RU, RPT,3,192.168.0.10:50000,FS1[CR][LF]
<Status>
0
1
2
3
Send ACK[CR][LF] when you receive a connection status message. If FA-10RU receives no
ACK, it re-sends the status message three times at one-second intervals.
Error Response
Return message (TCP): ERR<Error code>[CR][LF]]
Any of the following error messages is returned if a command is not properly received.
Error code
01-03
See the Error Code table in the previous section.
04
98
99
Disconnected
Connecting
Connection refused
Connected
62
Description
Description
Requests the connection status
between FA-10RU and USF-1043FS.
<FS number>
FS1 or --- (Disconnected)