IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be
followed including the following:
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before installation.
DANGER – Risque de choc – Couper l'alimentation avant l'installation.
2.
This luminaire must be installed in accordance with the NEC or your local
electrical code. If you are not familiar with these codes and requirements,
consult a qualified electrician.
Ce produit doit être installé conformément à NEC ou votre code
électrique local. Si vous n'êtes pas familier avec ces codes et ces
exigences, veuillez contacter un électricien qualifié.
3.
Suitable for Damp Locations.
Convient aux emplacements humides.
4.
Access above ceiling required. Do not install insulation within 3 inches (76
mm) of any part of the luminaire. Suitable for suspended ceilings.
Acces requis au-dessus du plafond. Ne pas mettre l'isolant a moins de 76
mm (3 po) de toute partie du luminaire. Convient aux plafonds suspendus.
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
• The FLEX Series of specification
troffers is for non-insulated
ceiling applications using T-Bar
ceiling grid, drywall grid adaptors,
and suspended mount.
• Designed for use in 120-277V
50-60 Hz or 347V 60Hz protected
circuit (fuse box, circuit breaker).
Supply wire sized as per NEC or
governing code(s), 90C rated.
TO INSTALL:
1
Luminaire Hooks
1 of 3
• Make sure to cap off all unused
leads.
• Lens and removable end cap may
shift during installation. To seat
lens press end caps and squeeze
lens to engage with back panel.
T-bar
Includes: FLX14™, FLX22™ and FLX24™
FLX14™
FLX22™
FLX24™
1st:
90° Bend
2nd: Bend
Against T-bar
T-bar
FLEX Series
Specification Troffers
INSTALLATION INSTRUCTIONS
T- BAR CEILING
MOUNTING
STEP 1:
Bring the FLEX troffer up into
the T-Bar grid.
STEP 2:
Locate the luminaire hooks and
bend them out 90 degrees for
installation. See Figure 1.
NOTE: The luminaire hooks
ship bent in and need to be
bent out for installation.
STEP 3:
Then bend the luminaire hooks
against the T-Bar to secure the
luminaire. See Figure 1.
LPN00437X0001A1_C

Advertisement

loading
Need help?

Need help?

Do you have a question about the FLEX Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cree FLEX Series

  • Page 1: Important Safeguards

    Acces requis au-dessus du plafond. Ne pas mettre l’isolant a moins de 76 mm (3 po) de toute partie du luminaire. Convient aux plafonds suspendus. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE • The FLEX Series of specification • Make sure to cap off all unused troffers is for non-insulated leads.
  • Page 2 SUSPENDED MOUNTING STEP 1: Attach customer supplied cables to the (2) cable slots on each side of the housing. See Figure 2. STEP 2: Attach customer supplied cables to mounting surface using customer supplied hardware. Ensuring that mounting surface can support the luminaire. Cable Slots 0 - 10V DIMMING OPTION STEP 1:...
  • Page 3 Secure incoming dimming leads to the existing strain relief, to prevent contact with primary wiring. © 2018 Cree, Inc. All rights reserved. For informational purposes only. Content is subject to change. See http://lighting.cree.com/warranty for warranty and specifications. Cree ®...

This manual is also suitable for:

Flx14Flx22Flx24