IDS816 INSTALLER MANUAL
Tamper by Zone
Individual zones may be enabled for tamper by zone. See page 7
Figure 2, for connection details. This feature is not available if zone
doubling is enabled. (See Figure 3, page 8 and Location 38 page 24)
Cross Zoning
This feature is useful for reducing false alarms. Violating zones with
the cross zone property enabled will not immediately generate an
alarm. The Cross Zone Delay Timer is started. See Location 36.
Depending on the value programmed into location 37 (Cross Zone Trip
Count) the zone (or any other zone with cross zone option enabled)
must trip the number of times programmed into location 37 before an
alarm is generated. An alarm will also be generated should the zone
remain violated for the entire delay period.
Swinger Shutdown
During a single arm cycle if the number of alarm violations generated
by a swinger zone equals the shutdown count (Location 33) the control
panel will automatically bypass the that zone.The swinger shutdown
counter is reset either when the system is disarmed and re-armed or
automatically when the 24 hour self test report is generated. See
Sublocation 5 of Locations 109 and110 [Partition Setup]
Silent Zone Enabled
This property allows any Follower, Instant, Panic and 24 Hour Alarm
Zone types to be programmed as a silent zone.
Z
o
n
e
R
e
p
Note:
For the following locations a two digit hexadecimal code must
be programmed. To disable a reporting code a double zero
(00) must be entered.
S
U
B
L
O
C
A
T
The code transmitted when the zone is violated during an arm cycle or
if a panic or 24 Hour Zone is violated.
20
IDS816 INSTALLER MANUAL NO. 700-283-02B ISSUED NOV 2004 VER 2.00