Pipe Connection; Minimum Space; Location - Grundfos Unilift AP12 Installation And Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

DANGER
Electric shock
Death or serious personal injury
- Route the power cable in a way
that supports it and protects it from
being cut, pinched or damaged.
- If the power cable is cut, pinched,
or damaged, replace it before
using the product.
DANGER
Electric shock
Death or serious personal injury
- Do not remove the power cable
and strain relief.
- Do not connect electrical conduit to
the pump.
Use an approved level controller with
a current rating that matches the
service factor marked on the
product's nameplate.

4.1 Pipe connection

Threaded steel or rigid plastic pipes can be
screwed directly into the 1.5" NPT outlet port.
For permanent installation, we recommend that
you fit a union, a non-return valve and an
isolating valve in the outlet pipe.
Other recommendations:
For portable or temporary installations, a
plastic outlet pipe can be used in conjunction
with a suitable, screwed connection or a
hose coupling.
Threads must be sealed using Teflon
Do not install the pump hanging from
the outlet pipe or hose.
Do not lift the pump by its power
cable. Lower and lift it by means of a
wire or chain fastened to the pump
handle.

4.2 Minimum space

When the pump is installed in a permanent
installation with a float switch, and the cable
length is set to the minimum length of at least
4 in. (100 mm), the minimum dimensions of the
sump pit, basin or tank must be as shown in
fig. 2.
In addition, the sump pit, basin or tank must be
sized according to the relation between the
water flow to the sump pit, basin or tank and the
pump performance.
Fig. 2

4.3 Location

The pump can be used in vertical as well as
horizontal position with the outlet port as the
highest point of the pump. See fig. 3.
During operation, the inlet strainer must always
be completely covered by the pumped liquid.
Fig. 3
®
tape.
When the pipe or hose has been connected,
place the pump in its operating position.
Position the pump so that the inlet strainer will
not be blocked by sludge, mud or similar
materials.
In a permanent installation, the installation site
must be cleared of sludge, pebbles, etc. before
the pump is installed.
We recommend that you place the pump on a
solid base. See fig. 4.
Fig. 4
21.5 in. (550 mm)
550 mm
Minimum installation dimensions
Pump positions
Pump placed on a plate
7