IPC6131-WD-A&6123-WDL-A&6232-IR&6212-
IR&6231-WD-VRZ&6332-MIR&6311-IR&6331-IR
User Guide
Figure 3-28 Install the Mount
Step 2 Fit the lens (not supplied) to the camera and rotate it to get it tightened.
NOTE
Step 3 Plug the auto-iris cable to the auto-iris interface.
Figure 3-29 Install the Lens
Step 4 Align the screw hole on the camera with the ceiling mount and rotate the camera to get it fixed.
Step 5 Adjust the surveillance angle.
1. Loosen the pan nut to adjust the pan angle [0°-360°].
2. Loosen the knob on the ceiling mount to adjust the tilt angle [0°-90].
Issue 02 (2014-12-25)
l Install the adapter ring to the lens interface if a C-mount lens is used.
l A manual-iris lens can be directly installed to the camera without plugging the power cable of the auto-
iris to the auto-iris interface.