Function Setting; Analog Input Signals; Functions Of Analog Input Signals - Mitsubishi LE-30CTN Instruction Manual

Tension controller
Table of Contents

Advertisement

6. Functions of Input/Output Signals
6.1.3

Function setting

• In the adjustment mode (power ON with DIP. SW8 OFF), select item number 50, and then set the function
of the input contact signal (MI1, MI2, or MI3).
Adjustment/setting
item selection screen
1
• Turn the setting dial(16). The following items will appear in the following order, and the displayed functions
are assigned to the MI1, MI2, or MI3.
(1) Output memory
(2) Output gain 1
(3) Output gain 2
(4) Output ON/OFF
(5) Manual output 1
(6) Manual output 2
6.2

Analog input signals

6.2.1

Functions of analog input signals

• Select item number 51 in the adjustment mode, and then assign the following functions to the analog input
signals (AI1, AI2).
• When the following functions are not necessary, it is not necessary to
assign the following functions.
1) Tension setting signal
• Enter the signal to set the tension for automatic operation using
the external analog voltage.
• For the input voltage range 0 to 5 V, the tension set range will be 0
to full-scale tension.
• When the function of the tension setting signal is assigned to the
[AI1] or [AI2], the tension cannot be set by using the setting
dial(16) in the panel.
2) External tension signal
• Input the tension signal excluding the signal of the LX-TD tension
detector.
• For the input signal range 0 to 5 V, the tension range will be 0 to
full-scale tension.
• When the function of the external tension signal is assigned to the
[AI1] or [AI2], the input signal from the tension detector to the
[GRL] - [WHL], or [GRR] - [WHR] will be ignored.
34
- - - - - - - - - - - - - - - - - - - - - - - - Item number : 50
On the adjustment/setting item selection screen, select item number 50, and
then press the
After selecting MI1, MI2, or MI3 with a screen selection keys (6) (
keys), select a function for MI1, MI2, or MI3 using the setting dial(16), and
then the function is selected by pressing the [SET] key.
When the function already set is specified, the function will be displayed as
"UNAVAIL".
F4
- - - - - - - - { [AI1], [AI2] } - [AIC]
key.
6.2 Analog input signals
and
Full-scale tension set in
adjustment mode using
item number [20].
0
0
1
2
3
4
Tension setting signal (V)
Full-scale tension set in
adjustment mode using
item number [20].
0
0
1
2
3
4
External tension signal (V)
5
5

Hide quick links:

Advertisement

Table of Contents
loading