12. Specifications
12.3

Set item list

Items of setting
Tension setting value
Full-scale value
Decimal point
Zero point tuning
Span adjustment target
value
Manual zero point
adjusting
Manual span adjusting
Zero tension setting
Tension display filter time
constant
Tension output filter time
constant
Manual output setting 1
Manual output setting 2
Taper rate
(internal calculation
method)
Taper rate
(external signal method)
Gain 1
Gain 2
Stop timer
Stop gain
Low excitation setting value
Proportional gain
Integral time
Additional gain
Dead band width
MI1 contact input
setting
MI2 contact input
setting
MI3 contact input
setting
AI1 analog input setting
AI2 analog input setting
Operation screen additional
setting 1
Operation screen additional
setting 2
Password setting
(Note)
[1] The data marked with [ ] in the "menu" column for the "Management of setting" column can be
stored in the menu function or read out from the menu function.
[2] The data marked with [ ] in the "menu" column for the "Management of setting" column can be set in
the adjustment mode only. Setting the item in the other modes is not possible.
[3] The data marked with [×] in the "Setting during operation" column cannot be changed while the run/
stop signal [RUN] is ON.
[4] The items marked with [ ] in the "Keyin" column can be set the keyin function.
50
Range of setting
Unit
Minimum
×
N,
10N
Minimum
×
N,
10N
1
---
0.01, 0.1, 1
---
0
1 to full-scale tension
×
N,
10N
(1/3 of full-scale value or more is
needed.)
×
N,
10N
-999
%
50
×
N,
10N
0
s
0.2 to 4.0
s
0.2 to 4.0
%
0
%
0
%
0
%
0
%
5
%
5
s
0.0
%
5
%
0
%
0
%
1
%
0
%
0
• Output memory
---
• Output gain 2
• Manual output
• Tension setting signal
• Winding diameter signal
• External tension signal
---
• Taper rate setting signal
• Manual setting signal 1
• Manual setting signal 2
10
---
10
---
0
Management of
Initial
value
Maximum
Menu System
Full-scale tension
200
2000
500
1
0
0
500
+999
0
300
100
full-scale tension
0
2.0
2.0
100
20
100
20
80
0
100
0
400
100
400
100
30.0
0.0
400
100
50
0
100
50
100
50
100
0
50
50
Not
set
• Output gain 1
Not
• Output ON/OFF
set
• Manual output 2
Not
set
Not
set
Not
set
53
0
53
0
30000
0
12.3 Set item list
Setting
setting
during
Keyin
operation
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
Item
No.
1
20
×
24
×
25
22
23
26
21
30
2
3
11
10
31
40
41
50
51
×
52
×
54