Mitsubishi Electric NP180 Series Setup Manual page 25

Narrow pixel pitch direct view led
Table of Contents

Advertisement

 If you click the "Sequential Numbering" button
again, the numbers will be re-assigned from
the top left corners.
 If you have connected the cables from other
LED units than described above, reassign an
appropriate ID for each LED unit in the cable
connection order.
5.
Click the "Apply" button to register the setting.
6.
The following window appears. Select "Yes"
then. "OK". The information of the LED unit
locations and ID numbers will be saved in the
control unit.
7.
By switching the control units in the "Control
unit" column, repeat the steps for other areas
according to the display configuration.
8.
When all the ID numbers of the LED units are
saved, click "Cancel" to exit the window.
9.
Display the "Crosshatch" internal test pattern (p.
38). The ID numbers have been properly set if
it is displayed with no problem. If not, check the
image signal cable connection and assign the
ID numbers again.
Power unit count (160 Series)
According to the configuration, enter the number
of the connected power units to each control unit.
 For a full HD resolution with the 15NP160 range,
input "3" and press "Enter" key to confirm.
Control unit location
It automatically sets the horizontal/vertical location
of the control units in an LED wall such as
H: 1, V: 1.
Select all the control units and click the "Set Unit
Location" button.
 Follow this procedure as well when you have
replaced a control unit.
Control unit 1
H:1, V:1
Control unit 3
H:1, V:2
Control unit 2
H:2, V:1
Control unit 4
H:2, V:2
Electrical adjustment