LEAD-ACID
CHARGING PROGRAMS
Settings are made by pressing the MODE-button. After about two seconds the charger acti-
vates the selected program. The selected program will be restarted next time the charger
is connected.
The table explains the different Charging Programs:
Program
Normal battery program 14.4V/2.3A
Only for lead-acid batteries.
Recond option 15.8V/0.9A
Use to restore capacity to WET and Ca/Ca batteries. Recond your
battery once per year and after deep discharge to maximise lifetime and
capacity.
READY TO USE
The table shows the estimated time for empty battery to 80% charge.
BATTERY SIZE (Ah)
5Ah
10Ah
15Ah
20Ah
25Ah
4 • EN
Explanation
TIME TO 80% CHARGED
2h
4h
6h
7h
9h
POWER LAMP
If the power lamp is lit with a:
1. STEADY LIGHT
The mains cable is connected to the wall socket.
2. FLASHING LIGHT
The charger has entered the energy save mode. This happens if the
charger can't detect a battery in 2 minutes.
ERROR LAMP
If the error lamp is lit, check the following:
1. Polarity error: Is the charger's positive lead connected to
the positive charging point?Is the charger's negative lead
connected to the negative charging point?
2. Is the charger connected to a 12V battery?
3. Has charging been interrupted in STEP 1, 2 or 5?
Restart the charger by pressing the MODE-button. If charging is still
being interrupted, the battery...
CHECK: ...is seriously sulphated and can not accept charge. The
battery may need to be replaced.
CARE: ...can not keep charge. The battery may need to be replaced.