LITHIUM
1
14.4V
Time limit:
5 minutes
STEP 1 WAKE UP
Read section about batteries with "under voltage protection" on previous page.
STEP 2 ACCEPT
Tests if the battery can accept charge. This step prevents that charging proceeds
with a defect battery.
STEP 3 BULK
Charging with maximum current until approximately 90% battery capacity.
STEP 4 ABSORPTION
Charging with declining current to maximize up to 100% battery capacity.
READY TO USE
The table shows the estimated time for empty battery to 80% charge.
BATTERY SIZE (Ah)
5Ah
10Ah
15Ah
20Ah
25Ah
2
3
Max
Max
14.2V/1.0A
14.2V/2.3A
30 minutes
20h
TIME TO 80% CHARGED
2h
4h
6h
7h
9h
4
5
Max 14.2V
Voltage limit
12.0V
4h
3 minutes
STEP 5 ANALYZE
Tests if the battery can hold charge. Batteries that can not hold charge may need to be
replaced.
STEP 6
Not applicable.
STEP 7 FLOAT
Maintaining the battery voltage at maximum level by providing a constant voltage charge.
STEP 8 PULSE
Maintaining the battery at 95–100% capacity. The charger monitors the battery voltage
and gives a pulse to keep the battery fully charged.
6
7
Max
13.3V/2.3A
13.8V/2.3A
Pulse start at 13.2V.
Pulse stop at 1.1A or
at time limit.
Max 1h pulse.
10 days
Auto pulse every
10 days
8
Max
EN • 7