Tekniske data

Kategori
Maksimal belasting Hø
Maksimal ydelse (u. kondensering)
Minimal ydelse
Maksimal ydelse (v. kondensdrift)
Minimal ydelse (v. kondensdrift)
Nyttevirkning ved 50/30°C
Nyttevirkning i.h.t. EU-direktiv 92/42
Maksimalt vandtryk i anlægget
Ekspansionsbeholderens volumen
Ekspansionsbeholderens fortryk
Maksimalt vandtryk i varmtvandsforsyningen bar
Indhold i varmtvandsbeholder
Varmtvandsydelse ved ∆T= 25 °C (**)
Varmtvandsydelse ved ∆T= 35 °C
Specifik varmtvandsydelse (*)
Varmtvandsydelse ved ∆T= 30 °C
Røggastemperatur min./max.
Max – røggastemperatur (udkoblingstemperatur)°C
Røggasmassestrøm (max)
Gasart
Gastryk - tilslutning
El-tilslutning
Strømfrekvens
Maksimal effektforbrug
Sikring
Radiostøjdæmpning iht.
Nettovægt
Mål
Tæthedsgrad mod fugtighed og indtrængning af vand IP X4D
Temperaturindstilling af varmt vand
Drifttemperatur, varmeanlæg radiator
Drifttemperatur, varmeanlæg gulvvarme
Frostbeskyttelse af kedel og varm
tvandsbeholder
Max. længde af lodret bal. aftræk
Max. længde af splitaftræk luft og røg
Max. længde af vandret bal. aftræk
For hver 90° bøjning reduceres længden med 1 meter.
For hver 45° bøjning reduceres længden med 0,5 meter.
Godkendelser:
VA – godkendelse:
CE – nr:
GARANTI:
5
mod korrosion af røggasberørte dele og
års
varmtvandsbeholderen.
2 års garanti på øvrige dele i h.t. BAXI-garantibevis.
(*) ifølge EN 625
(**) opnås ved at blande med koldt vand
(***) afstandskrav fra sider: + 20mm.
1000 W = 860 kcal/h
1 mbar = 10,197 mmH
O = 10
2
kW
kW
kW
kW
kW
%
bar
l
bar
l
l/min
l/min
l/min
l/30 min
°C
g/s
G.20 -dansk naturgas
mbar
V
Hz
W
A
CE EN-norm
kg
højde
mm
bredde (***)
mm
dybde
mm
°C
°C
°C
°C
m
m
m
VA 3.21/DK12157
0085AS-0525
-1
kPa

Technical data

I
Category
2H
25,3
Maximum load High
Maximum output (without condensing)
22,8
Minimum output
6,5
Maximum output (during condensing)
23,9
Minimum output (during condensing)
6,8
Efficiency at 50°/30° C
105
Efficiency in accordance with EU Directive 92/42
****
Maximum water pressure in the appliance
2,5
Expansion vessel volume
7,5
Expansion vessel pre-set pressure
0,5
10
Maximum water pressure in the hot-water supply bar
60
Content of the hot-water cylinder
13,3
Hot-water output at ?T = 25°C (**)
9,5
Hot-water output at ?T = 35°C
16
Specific hot-water output (*)
390
Hot-water output at ?T = 30°C
Flue-gas temperature min/max
40/70
Max flue-gas temperature (disconnection temperature) °C
90
Flue gas bulk flow (max)
10,8
Gas type
Gas pressure – connection
20
230
Electrical connection
50
Current frequency
190
Maximum energy consumption
2
Fuse
92/31
Radio interference filter in accordance with CE EN-norm 92/31
73
Net weight
950
Dimensions
600
450
Degree of tightness to moisture and ingress of water
10-60
Temperature setting of hot water
25-85
Operating temperature, radiator heating system
25-45
Operating temperature, floor heating system
Frost protection of boiler and hot-water cylinder °C
5
7,5
Max. length of vertical balanced flue
10+10
Max. length of split flue for air and flue gas
9
Max. length of horizontal balanced flue
For each 90° bend, the length is reduced by 1 metre
For each 45° bend, the length is reduced by 0.5 metre
Approvals:
VA approval:
CE no.:
GUARANTEE:
5 years against corrosion of parts in contact with flue gas and the
hot-water cylinder
2 years' guarantee on other parts in accordance with the BAXI
guarantee certificate
(*) in accordance with EN 625
(**) achieved by mixing with cold water
(***) clearance requirements from sides: + 20 mm
1000 W = 860 kcal/h
1 mbar = 10.197 mmH
35
l/min
l/min
l/min
l/30 min
G.20 - dansk naturgas
mbar
height
width (***) mm
depth
VA 3.21/DK12157
0085AS-0525
-1
0 = 10
kPa
2
I
2H
kW
25,3
kW
22,8
kW
6,5
kW
23,9
kW
6,8
%
105
****
bar
2,5
l
7,5
bar
0,5
10
l
60
13,3
9,5
16
390
°C
40/70
90
g/s
10,8
20
V
230
Hz
50
W
190
A
2
kg
73
mm
950
600
mm
450
IP X4D
°C
10-60
°C
25-85
°C
25-45
5
m
7,5
m
10+10
m
9