LODRET BALANCERET AFTRÆK MED LUFT FRA
EKSISTERENDE AFMELDT SKORSTEN
Hvor forholdene taler herfor anvendes ovennævnte LODRET balanceret
aftræk - hvorved forstås at luften tages ind via afmeldt eksisterende afmeldt
skorsten og røggas ledes ud samme sted (Gennem hætte (for balanceret
lodret aftræk) der lader luften gå ned gennem en eksisterende skorsten).
Tilslutningssæt aftræk/luft via skorsten består af:
1 stk. Top til skorsten.
1 stk. Taggennemføring m. hætte.
1 stk. Split tilslutningssæt Ø 80.
Desuden skal bruges:
• Lige rør Ø 80 til luft eller røggas (Til røggas skal anvendes rustfri, til
luft anvendes aluminium)
• Max totallængde af aftræk + luftrør = 10+10 m minus 1 m for hver 90°
bøjning (0,5 m pr. 45° bøjning)
• Bøjning 15º, 30º, 45° eller 90° (Til røggas skal anvendes rustfri, til luft
anvendes aluminium)
• Murbøsninger
• Evt. rørbærer for røgrør og luftrør
• Silikone
Montage af lodret balanceret aftræk, hvor den eksisterende afmeldte
skorsten anvendes til føring af røggasrør og til lufttransport.
• Skorstenen skal være afmeldt og skal være renset meget omhyggeligt
for at undgå, at der suges snavs ind i gaskedlen.
• Minimum diameter af skorsten Ø 130
• Max totallængde af aftræk = 10+10 m minus 1 m for hver 90° bøjning
(0,5 m pr. 45° bøjning)
1. Benyt silikone el. lign. for vandtæt samling.
2. Topstykket skrues forsvarligt på top af skorsten.
3. Røgaftræksrørene monteres på "taggennemføring m. hætte", og alle
System L3
Taggennemføring m/hætte
Roof duct with cover
Top til skorsten
Cap for chimney
Rør Ø80 (rustfri)
Pipe Ø80 (rust-resistant)
L = 250
L = 500
L = 1000
Bøjning 90
90
Murbøsninger
Wall bushes
VERTICAL BALANCED FLUE WITH AIR FROM EXISTING
Where indicated by the conditions, use the aforementioned VERTICAL
balanced flue – which means that the air is taken in via an existing disused
chimney and the flue gas is directed out at the same place (through the
cover (for the balanced vertical flue) which allows the air to go down
through an existing chimney).
The connecting set for flue/air via a chimney consists of:
1 cap for the chimney
1 roof duct with cover
1 split connecting set Ø 80.
In addition, the following must be used:
• Straight pipe Ø 80 for air or flue gas (use rust-resistant for flue gas,
aluminium for air)
• Maximum total length of flue + air pipe = 10 + 10 m minus 1 m for
each 90° bend (0.5 m for each 45° bend)
• 15°, 30°, 45° or 90° bend (use rust-resistant for flue gas, aluminium
for air)
• Wall bushes
• If necessary, pipe clamps for flue pipe and air pipe
• Silicone
Installation of vertical balanced flue, where the existing disused
chimney is used to carry the flue gas pipe and to convey air .
°
Ø80 (rustfri)
°
bend Ø80 (rust-resistant)
Split tilslutningssæt
Split connecting set
• The chimney must be disused and must be cleaned very carefully in
order to prevent dirt being sucked into the gas boiler.
• Minimum diameter of the chimney Ø 130
• Maximum total length of flue = 10 + 10 m minus 1 m for each 90°
bend (0.5 m for each 45° bend)
1. Use silicone or similar for a water-tight joint.
2. Screw the top section securely on top of the chimney.
3. Fit the flue pipes to the "roof duct with cover", and lower all of the
16
DISUSED CHIMNEY