Oc12 Pos Line Card Error Messages; Cli-Controlled Oir - Cisco 7300-1OC12POS-MM Installation And Configuration Manual

Oc12 packet over sonet line card
Table of Contents

Advertisement

Chapter 4
Configuring the OC12 POS Line Card

OC12 POS Line Card Error Messages

The only error messages you should see are of the following type and format:
%POS-1-INITFAIL: POS4/0 initialization failed
%POS-1-HWFAIL: POS OC12(4) Hardware failure. Primary DDLL not set. Deactivating line card.
%POS-3-FPGAREVNOTSUPPORTED:POS OC12(4) Line card requires fpga revision of (2).Current
fpga revision is (0)
%POS-3-FPGAREVNOTMATCH:POS OC12(4) Line card fpga requires min h/w revision of (0.0)
%POS-1-TRESFAIL:POS OC12(4/0) Failed to obtain PXF resources, error=16, shutting down
interface
%POS-1-HWFAIL:POS OC12(4) Hardware failure. Secondary DLL not set.
Contact the Technical Assistance Center (TAC) for assistance with these error messages. To contact the
Note
TAC, see the

CLI-Controlled OIR

Line cards can be removed from the Cisco 7304 router without disrupting data flow by using the
hw-module slot slot # stop/start command in EXEC mode. The hw-module slot slot # stop command
will stop traffic, shut down all line card interfaces, and deactivate the line card. The hw-module slot slot
# start command resets the line card, puts the line card back online, and turns off the OIR LED. To
remove and install an active line card in slot 2, proceed as follows:
Router# hw-module slot 2 stop
When the OIR LED turns green, the line card in slot 2 has been deactivated and can be physically
removed and replaced with a new line card (see the
page
When the new line card is inserted in slot 2 it is automatically reset, put online, and the OIR LED is
turned off.
OL-3437-01
"Obtaining Technical Assistance" section on page
3-3).
9.
"Line Card Removal and Installation" section on
OC12 Packet Over SONET Line Card Installation and Configuration
OC12 POS Line Card Error Messages
4-13

Advertisement

Table of Contents
loading

Table of Contents