Installation

Weight of Equipment

Model
UHCTHD6
UHCTHD3

Clearance Requirements

Minimum clearance requirements are the same for
noncombustible locations as for combustible locations.
The flooring under the appliance must be made of a
noncombustible material.
Risk of fire/shock. All minimum clearances must be
maintained. Do not obstruct vents or openings.
Sides/Back 1.0" (25mm)

Dimensions

Model
Width
22.2"
UHCTHD6
(56.3cm)
22.2"
UHCTHD3
(56.3cm)

Electrical Service

Check all wiring connections, including factory
terminals, before operation. Connections can become
loose during shipment and installation.
Copper wire suitable for at least 167°F (75°C) must be
used for power connections.
n
All units should be connected to a grounded power
supply system.
RATED VOLTAGES, CYCLES, PHASES, WATTAGE, AMPERAGES & POWER CORD CHART
Units with plugs are supplied with approximately six (6) to ten (10) foot cords.
Model
UHCTHD6
UHCTHD3
2-2
Weight
195.6 lbs (88.7kg)
120lbs (54kg)
DANGER
DANGER
Depth
Height
25.8"
26.0"
(65.4cm)
(66.0cm)
25.8"
16.6"
(65.4cm)
(42.2cm)
DANGER
DANGER
Warning
Voltage, Cycle, Phase
200-240V, 50/60H, 1Ph
200-240V, 50/60H, 1Ph
This appliance must be grounded and all field wiring
must conform to all applicable local and national
codes. Refer to rating plate for proper voltage. It is the
responsibility of the end user to provide the disconnect
means to satisfy the authority having jurisdiction.
All electrically operated appliances must be electrically
grounded in accordance with local codes, or in the
absence of local codes, with national electric code,
ANSI/NFPA NO. 70-1990.
This appliance is equipped with a three-prong
grounding plug for your protection against shock
hazard and must be plugged into a properly grounded
three-prong receptacle.
grounding prong from this plug.

VOLTAGE

All electrical work, including wire routing and
grounding, must conform to local, state and national
electrical codes. The following precautions must be
observed:
The equipment must be grounded.
A separate fuse/circuit breaker must be provided
for each unit.
A qualified electrician must determine proper
wire size dependent upon location, materials
used and length of run (minimum circuit ampacity
can be used to help select the wire size).
The maximum allowable voltage variation is ±10%
of the rated voltage at equipment start-up (when
the electrical load is highest).
Check all green ground screws, cables and wire
connections to verify they are tight before start-
up.
Watts
Amps
2400-2900
12.0
1670-2400
8.3-10.0
Warning
n
Warning
n
Warning
n
DO NOT cut or remove the
Plug
320P6W/316P6/31-38015
320P6W/316P6/31-38015