10.2.7 Remote control and external trig

This cable connects the EM 710 Transceiver Unit to a remote
On/Off switch, normally located in a Remote Control junction
box.
The same connection allows trigger output and remote control
(synchronization) with a serial line.
Junction box
Terminal block
1
2
3
4
5
6
7
8
9
TRIG OUT
TRIG GND
Trigger out to
external system
(synchronization)
Serial line to/from
external system (synchronization)
NSEM Remote On/Of f control and synchronization
W245 / Rev . A
• Conductors: 5 x 2 x 0.5 mm²
• Screen: Overall braided
• Voltage: 60 V
• Maximum diameter: Limited by the plugs
Installation drawings
Trigger out (TRIG OUT)
Trigger ground (TRIG GND)
Standby + (+24V)
Standby - (24V GND)
On (ON)
Ground (GND)
Ready to send / blanking (R
TS)
Trig in (CTS)
Not connected (NC)
Junction box
1
2
3
4
5
GND
6
RTS
7
CTS
8
System On/Of f
9
Local 9-pin
D connector
1
2
3
4
5
6
7
8
9