  • Page 1 Sun StorageTek PCI-X Enterprise ™ 2 Gb FC Single Port Host Bus Adapter Installation Guide Sun Microsystems, Inc. www.sun.com Part No. 819-4487-11 January 2007, Revision A Submit comments about this document at: http://www.sun.com/hwdocs/feedback...
  • Page 2 Copyright 2007 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, Californie 95054, Etats-Unis. Tous droits réservés. Sun Microsystems, Inc. a les droits de propriété intellectuels relatants à la technologie qui est décrit dans ce document. En particulier, et sans la limitation, ces droits de propriété...
  • Page 3: Table Of Contents

    Contents Preface v Installing, Connecting, and Testing the Host Bus Adapter 1 Software Requirements 2 Device Drivers 2 Tools and Equipment Needed 3 Preparing for Installation 3 Sun Enterprise Systems 4 Preparing for a Sun StorEdge A5x00 Installation 5 Installing the Host Adapter 8 Testing the Installation 11 SunVTS 11 Testing Procedure 12...
  • Page 4 To Specify the New Boot Disk as the Boot Device. 34 Declaration of Conformity, Regulatory Compliance, and Safety Statements 37 Declaration of Conformity 39 Regulatory Compliance Statements 41 Safety Agency Compliance Statements 45 Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 5: Preface

    Preface This guide describes how to install the Sun StorageTek™ PCI-X Enterprise 2Gb FC Single Port host bus adapter and how to update the driver. How This Book Is Organized The single chapter describes how to install the HBA and update the driver. Appendix A provides the safety, regulatory, and compliance information for the product.
  • Page 6: Related Documentation

    Part Number Latest information 819-4488-xx Sun StorageTek(TM) PCI-X Enterprise 2Gb FC Single Port Host Bus Adapter Release Notes Locating documents Accessing Documentation 819-1209-xx vi Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 7 Accessing Sun Documentation You can view, print, or purchase a broad selection of Sun documentation, including localized versions, at: http://www.sun.com/documentation Third-Party Web Sites Sun is not responsible for the availability of third-party web sites mentioned in this document. Sun does not endorse and is not responsible or liable for any content, advertising, products, or other materials that are available on or through such sites or resources.
  • Page 8 Please include the title and part number of your document with your feedback: Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide, part number 819-4487-11. viii Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 9: Installing, Connecting, And Testing The Host Bus Adapter

    SG-XPCI1FC-QL2) in three simple steps. Throughout this document, the term “HBA” is used interchangeably with the words “Host Bus Adapter.” Caution – Keep the Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port HBA in the antistatic bag until installation. The Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port HBA contains parts that can be damaged by electrostatic discharge (ESD).
  • Page 10: Software Requirements

    Go to the URL listed in the Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port ■ Host Bus Adapter Release Notes to download the Fibre Channel transport device driver patches or, for updates, go to: http://sunsolve.sun.com. Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 11: Tools And Equipment Needed

    Tools and Equipment Needed You may need to order fiber optic cables. You can order them in the following lengths: two-meter, part number X9722 ■ five-meter, part number X9723A ■ 15-meter, part number X9724 ■ SC-SC coupler X9720A ■ You will also need: A No.
  • Page 12: Sun Enterprise Systems

    Note – If the JTAG jumper is installed, the PCI I/O board will not be recognized or initialized during POST (power-on self-test) nor will it subsequently be recognized by the operating system. JTAG Jumper FIGURE 1 Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 13: Preparing For A Sun Storedge A5X00 Installation

    Preparing for a Sun StorEdge A5x00 Installation 1. Use the array’s front panel module (FPM) to ensure that the firmware level of the interface boards is at least 1.05. Firmware revision must be at least 1.05 Menu screen Interface board Interface board level 3 screen level 2 screen...
  • Page 14 For systems that have more than one system board, you must also select and remove a system board that has an available PCI slot. Refer to your system documentation for specific instructions. Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 15 9. Attach the antistatic wrist strap to your wrist and to a metal component on the system chassis. The wrist strap between you and the chassis provides the ground path necessary to safely remove and install the printed circuit boards and components without damaging them.
  • Page 16: Installing The Host Adapter

    Refer to your system documentation for specific instructions. 4. Disconnect the wrist strap. 5. Push the fiber optic cable connector into the OT connector until you hear a click. Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 17 Caution – Fiber optic cables have keyed connectors; they can only be inserted into OT connectors. 6. Connect the other end of the fiber optic cable to a device such as an array, switch or hub. Caution – In multiple-initiator configurations, when a Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port HBA is directly connected to a Sun StorEdge A5x00, each port on the host adapter must be connected to a separate loop on the A5x00.
  • Page 18 /SUNW,UltraSPARC-II@1,0 /SUNW,UltraSPARC-11@0,0 /fhc@0,f8800000 /central@1f,0 /virtual-memory /memory@0,0 /aliases /options /openprom /chosen /packages /pci@f,4000/SUNW,isptwo@3 /pci@f,4000/SUNW,isptwo@3/st /pci@f,4000/SUNW,isptwo@3/sd /fhc@e,f8800000/sbus-speed@0,500000 /fhc@e,f8800000/eeprom@0,300000 /fhc@e,f8800000/flashprom@0,0 /fhc@e,f8800000/environment@0,400000 /fhc@e,f8800000/ac@0,1000000 /pci@e,2000/pci@2 /pci@e,2000/pci@2/SUNW,qlc@1 /pci@e,2000/pci@2/SUNW,qlc@1/fp@0,0 /pci@e,2000/pci@2/SUNW,qlc@1/fp@0,0/disk Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 19: Testing The Installation

    , /pci@e,0/pci@1/pc1@1/SUNW,qlc@5 is one port on the Sun CODE EXAMPLE 2 StorageTek PCI-X Enterprise 2 Gb FC Single Port HBA and the disks are in a Sun StorEdge A5000 array (SENA). Note – The probe-scsi-all command does not function identically on all platforms, and does not in all cases probe for fiber channel devices.
  • Page 20: Testing Procedure

    This is a good way to test your fiber loop if you leave the qlc port attached to storage devices. Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 21: Booting From The Network Adapter

    Booting From the Network Adapter Booting from the network adapter requires special procedures in order to enable detection of installation devices. To boot from the small kernel image on the network adapter, you must use either a boot/install server or a temporarily directly- connected boot disk to enable bootability.
  • Page 22: Overview Of The Net Installation Method

    1. For the distinction between these two types of server, see the Solaris system administration documentation. Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 23: To Set Up The Boot/Install Server

    3. The client boots from the boot/install server, the interactive suninstall(1M) application starts, and the system administrator provides configuration information requested at the prompts. 4. After the system administrator provides all configuration information requested by the installation program, the installation of the Solaris operating environment begins.
  • Page 24 Caution – Do not use the patchadd(1M) command line that is given in the README to install the patch(es). See “To Modify the Boot Image” on page 17 to install relocatable versions of the patch(es). Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 25: To Modify The Boot Image

    To Modify the Boot Image ▼ 1. Install the driver packages into the boot image. The following example installs all packages previously downloaded into the /<export_public> directory. Note – Refer to the install_order file for the proper order in which to install the packages.
  • Page 26: To Set Up The Client

    (:), followed by /<export_public> followed by /mnt. The following example uses boot_install_server as the name of the boot/install server. /<export_public> # mount boot_install_server: /a/mnt Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 27 6. Install the driver packages into the install image. The following example installs all packages previously downloaded into the /<export_public> directory. When prompted, install the packages in the order of SUNWsan, SUNWcfpl, SUNWcfplx. # cd /a/mnt # pkgadd -R /a -d . 7.
  • Page 28: The Dump And Restore Method

    ■ “To Specify Slices On the New Boot Disk” on page 25 ■ “To Label the New Boot Disk” on page 29 ■ Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 29: To Prepare To Partition The New Disk

    ▼ To Prepare To Partition the New Disk 1. Switch users to root on the host with the host adapter. % su Password: 2. If the driver and any needed patches are not already installed, download the driver package from Sun’s download center and install it on the host, following the instructions in the README file that comes with the driver.
  • Page 30 3. Specify the disk where the operating system is installed on the temporary boot disk. The following screen example specifies disk 2. Specify disk (enter its number): 2 Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 31 4. Enter the partition command to bring up the PARTITION MENU. format> partition PARTITION MENU: - change ‘0’ partition - change ‘1’ partition - change ‘2’ partition - change ‘3’ partition - change ‘4’ partition - change ‘5’ partition - change ‘6’ partition - change ‘7’...
  • Page 32: To Change To The New Boot Disk

    After you record the partition layout, change to the new boot disk. 1. At the format> prompt, type disk to change the current disk to the new boot disk. Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 33: To Specify Slices On The New Boot Disk

    2. Enter the number of the disk to be formatted after the disk command. The following screen example uses disk 2. The FORMAT MENU appears. format> disk 2 selecting c7t16d0 [disk formatted] FORMAT MENU: disk - select a disk type - select (define) a disk type partition - select (define) a partition table...
  • Page 34 (24620/0/0) 71127180 3 unassigned (0/0/0) 4 unassigned (0/0/0) 5 unassigned (0/0/0) 182 - 24619 33.67GB (24438/0/0) 70601382 7 unassigned (0/0/0) Enter partition id tag[root]: Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 35 3. Enter the partition ID tag. The following example shows a question mark (?) entered after the prompt. The list of accepted partition id tags displays. The example then shows the default partition id tag of root accepted by pressing the Return key. Enter partition id tag[root]: ? Expecting one of the following: (abbreviations ok): unassigned...
  • Page 36 - save new disk/partition definitions inquiry - show vendor, product and revision volname - set 8-character volume name !<cmd> - execute <cmd>, then return quit format> Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 37: To Label The New Boot Disk

    ▼ To Label the New Boot Disk After you specify the slices on the new boot disk, label the new boot disk with the new partition table. 1. Enter the label command format> label 2. Enter y[es] to continue. Ready to label disk, continue? y 3.
  • Page 38: To Create Files Systems On The New Boot Disk

    “To Copy the Contents of Non-root File Systems onto the New Boot Disk” on ■ page 33 “To Specify the New Boot Disk as the Boot Device.” on page 34 ■ Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 39: To Copy The Boot Block And Root File System Contents To The New Boot Disk

    ▼ To Copy the Boot Block and Root File System Contents To the New Boot Disk 1. Install the boot block on the root (/) file system of the new disk. The following example uses the installboot(1M) command to install the boot block.
  • Page 40: To Update The Vfstab File

    The following example shows the disk name c0t0 changed to c3t8 in the mount table entries for slices 0, 1, and 7. /dev/dsk/c7t16d0s1 swap /dev/dsk/c7t16d0s0 /dev/rdsk/c7t16d0s0 1 no /dev/dsk/c7t16d0s7 /dev/rdsk/c7t16d0s7 /home 2 yes - Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 41: To Copy The Contents Of Non-Root File Systems Onto The New Boot Disk

    ▼ To Copy the Contents of Non-root File Systems onto the New Boot Disk 1. Mount the file system onto the /mnt mount point. This example shows the copying of the /home file system from slice 7 to the new boot disk.
  • Page 42: To Specify The New Boot Disk As The Boot Device

    Enter the setenv command followed by the boot-device parameter followed by the name of the new disk. ok setenv boot-device disk2 b. Enter the reset command. ok reset Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 43 5. Enter the boot command with the -r option so that the Solaris operating environment can recognize the adapter. ok boot -r Installing, Connecting, and Testing the Host Bus Adapter...
  • Page 44 Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 45: Declaration Of Conformity, Regulatory Compliance, And Safety Statements

    A P P E N D I X Declaration of Conformity, Regulatory Compliance, and Safety Statements This appendix contains the following information that applies to the Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter: “Declaration of Conformity” on page 39 ■...
  • Page 46 Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 47: Declaration Of Conformity

    Compliance Model Number: FC5010409 Product Family Name: Sun StorageTek PCI-X Enterprise 2Gb FC Single Port HBA (SG-XPCI1FC-QL2) USA - FCC Class B This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1.
  • Page 48 Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 49: Regulatory Compliance Statements

    Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. Modifications: Any modifications made to this device that are not approved by Sun Microsystems, Inc. may void the authority granted to the user by the FCC to operate this equipment.
  • Page 50 ICES-003 Class A Notice - Avis NMB-003, Classe A This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. ICES-003 Class B Notice - Avis NMB-003, Classe B This Class B digital apparatus complies with Canadian ICES-003.
  • Page 51 BSMI Class A Notice The following statement is applicable to products shipped to Taiwan and marked as Class A on the product compliance label. T33012 D33012 CCC Class A Notice The following statement is applicable to products shipped to China and marked with “Class A” on the product’s compliance label.
  • Page 52 Sun StorEdge 2 Gb FC Entry-Level PCI-X Single Channel HBA Installation Guide • January 2007...
  • Page 53: Safety Agency Compliance Statements

    Do not make mechanical or electrical modifications to the the equipment’s electrical rating label. equipment. Sun Microsystems is not responsible for Never push objects of any kind through openings in ■ regulatory compliance of a modified Sun product.
  • Page 54 Do not connect the power cord when the power supply has been removed from the system chassis. Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 55 Rack System Warning CD and DVD Devices The following warnings apply to Racks and Rack Mounted The following caution applies to CD, DVD, and other systems. optical devices. Caution – For safety, equipment should Caution – Use of controls, adjustments, or the always be loaded from the bottom up.
  • Page 56 Conformité SELV cordons d'alimentation. Le niveau de sécurité des connexions E/S est conforme aux normes SELV. Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 57 Mise en garde relative aux batteries Attention – Afin d'éviter que le rack ne penche pendant l'installation du matériel, tirez Attention – Les batteries risquent d’exploser la barre anti-basculement du rack. en cas de manipulation maladroite ou de remplacement incorrect. Pour les systèmes dont les batteries sont remplaçables, effectuez Attention –...
  • Page 58 70 dB(A). Achtung – Gefährliche Spannungen. Befolgen Sie die Anweisungen, um Stromschläge und Verletzungen zu vermeiden. SELV-Konformität Der Sicherheitsstatus der E/A-Verbindungen entspricht den SELV-Anforderungen. Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 59 Anschluss des Netzkabels Warnung bezüglich Batterien Achtung – Sun-Geräte sind für Achtung – Bei unsachgemäßer Handhabung Stromversorgungssysteme mit einem oder nicht fachgerechtem Austausch der geerdeten neutralen Leiter (geerdeter Batterien besteht Explosionsgefahr. Verwen- Rückleiter bei gleichstrombetriebenen den Sie bei Systemen mit austauschbaren Geräten) ausgelegt.
  • Page 60 Achtung – Die hier nicht aufgeführte Verwendung von Steuerelementen, Anpassungen oder Ausführung von Vorgängen kann eine gefährliche Strahlenbelastung verursachen. Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 61 Precaución – No todos los cables de alimentación tienen la misma clasificación No realice modificaciones de tipo mecánico ni eléctrico en el equipo. Sun Microsystems no se hace responsable del eléctrica. Los alargadores de uso doméstico no cuentan con protección frente a sobrecargas y cumplimiento de normativas en caso de que un producto no están diseñados para su utilización con...
  • Page 62 De lo contrario, puede sufrir lesiones Luokan 1 Laserlaite personales y ocasionar daños en el sistema. Klasse 1 Laser Apparat Laser Klasse 1 Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...
  • Page 63 Dispositivos de CD y DVD La siguiente medida se aplica a los dispositivos de CD y DVD, así como a otros dispositivos ópticos: Precaución – La utilización de controles, ajustes o procedimientos distintos a los aquí especificados puede dar lugar a niveles de radiación peligrosos.
  • Page 64 Sun StorageTek PCI-X Enterprise 2 Gb FC Single Port Host Bus Adapter Installation Guide • January 2007...

Table of Contents