54 | HTD 6xx / HTD 8xx | Calibration device
4. Plug the low-voltage connector of the power supply
unit into the calibration device
Fig. 5:
Power supply unit connector
5. Connect the cable of the power supply unit to the
mains voltage (230 V).
6. Set the selector switch of the power supply unit to
13.8 V (simulated motor vehicle alternator voltage).
7. Switch on the calibration device.
i
The Power switch is located on the back of the calib-
ration device near the fan.
Fig. 6:
Power switch
"
The calibration device is then ready for operation.
"
Low beam or high beam can be switched on. To do so,
the switch on the top must be set to 1 or 2.
|
1 692 106 011
2019-03-26
3.3.3

Calibration device 1 692 104 300

1. Set up the calibration device on a surface parallel to
the floor at a height of 70 to 80 cm.
2. If necessary, adjust the parallelism of the calibrati-
on device with respect to the floor by means of the
height adjustable feet.
i
When perfectly parallel, the spirit level which can be
seen from above will be in the center of the round
black mark.
Fig. 7:
Leveling
3. Plug the low-voltage connector of the power supply
unit into the calibration device.
Fig. 8:
Power supply unit
4. Connect the cable of the power supply unit to the
mains voltage (230 V).
5. Switch on the calibration device.
"
The calibration device is then ready for operation.
"
Low beam or high beam can be switched on. To do so,
the switch on the top must be set to 1 or 2.