Download Print this page
olympia electronics GR-939/30L/LT Quick Start Manual

olympia electronics GR-939/30L/LT Quick Start Manual

Waterproof self testing maintained emergency luminaires

Advertisement

Quick Links

WATERPROOF SELF TESTING MAINTAINED EMERGENCY LUMINAIRES
TECHNICAL CHARACTERISTICS
OPERATION VOLTAGE
MAXIMUM POWER CONSUMPTION
BATTERIES (Ni-ΜΗ)
BATTERY PROTECTION
EXPECTED BATTERY LIFETIME
INDICATIONS - CONTROLS
CHARGING TIME
MINIMUM AUTONOMOUS DURATION
ILLUMINATION SOURCE
ILLUMINATION (MAINS / EMERGENCY)
DEGREES OF COVER PROTECTION
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
RELATIVE HUMIDITY
CONSTRUCTION MATERIALS
EXTERNAL DIMENSIONS
TYPICAL WEIGHT
GUARANTEE
GENERAL
This luminaire is used in places with low
t e m p e r a t u r e ( - 2 0 C ) w h e r e e m e r g e n c y
luminaires are needed.
Each illumination sign must be permanently
connected to mains power supply. In normal
operation the led strip lights and the battery is
charging. In case of a mains power supply
failure the illumination sign will light the led
strip automatically in emergency mode. When
the mains power supply is restored the device
turns to normal operation.
INSTALLATION
To install the luminaire follow the installation
instructions on page 3.
Battery Charging
The battery charging is completely controlled.
In this case, is achieved the perfect battery
maintenance, as well as the elongation of its
duration. When the battery has completely
charged, it charges with a maintenance
current.
Battery Cut-off
The luminaire enters in this operation when the
mains power supply fails and battery has lost
its
energy.
During
illumination sign enters the idle state and
battery consumption is negligible, in order to be
protected from deep discharge.
Page 1 from 5
ΤΕΧΝΙΚΑ ΧΑΡΑΚΤΗΡΙΣΤΙΚΑ
EN 60598-1, EN 60598-2-22, ΕΝ 55015, ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
Thank you for your trust in our products.
Olympia Electronics - European manufacturer.
o
this
operation
(for LED MODULE Specifications see page 4)
GR-938/30L/LT
220-240VAC 50-60Hz
31W / 33VA (<0°C)
3.6V / 2Ah
From overcharge and deep discharge
4 years
Charge, Lamp fault, Battery fault , TEST button
90 min
White LEDs
280lm / 230lm
-20 to +40 C
Up to 95%
Bayblend FR3010, transparent polycarbonate
363 x 145 x 73 mm
940gr.
3 years (1 year for the battery)
Manual Test
The manual test can be conducted only if the
mains
power
connected. By pressing the TEST/RESET
button briefly (page 3) an emergency operation
test is initiated. During this test period all
indication LEDs are OFF.
Automatic Operational Test
This test includes all the operations that provide
the manual test and is conducted automatically
every 15 days. In order to be performed, the
mains power supply and the battery should be
connected.
Manual Autonomous Test
If the Test button is pressed for a period
between 5 to 10 seconds (with the battery fully
charged), the illumination sign will enter in
counting autonomy condition. If the battery is
not fully charged this command is ignored. The
BATTERY
measurement, indicating this process to the
user. This measurement duration is equal with
the nominal autonomous duration of the
illumination sign (1.5 hour or 3 hours) and at the
end of the process, if the measured duration
the
was at least the nominal autonomous duration,
the BATTERY FAULT is turned OFF, in the other
hand stays continuously ON indicating to the
GR-939/30L/LT
32W / 35VA (<0°C)
3.6V / 4Ah
24h
180 min
IP65
o
1050gr.
supply
and
the
FAULT
blinks
923939016_09_007
battery
is
during
the

Advertisement

loading

Summary of Contents for olympia electronics GR-939/30L/LT

  • Page 1 TYPICAL WEIGHT GUARANTEE 3 years (1 year for the battery) Thank you for your trust in our products. Olympia Electronics - European manufacturer. GENERAL Manual Test This luminaire is used in places with low The manual test can be conducted only if the...
  • Page 2: Labeling Explanation

    user that the battery must be replaced. ΑΤΤΕΝΤΙΟΝ!!! Automatic Autonomous Test 1. Operations for installation, maintainance or The Automatic Autonomous Test is conducted testing must be done by authorized personnel and measures the illumination sign’s back up only. operation and emergency duration. This test is 2.
  • Page 3: Installation Instructions

    INSTALLATION INSTRUCTIONS L1 L N Step 1. Remove the diffusor. Place a flat blade screwdriver and pull the reflector gently (with opposite orientation in relation to the plastic base). Step 2. Install the included plastic cover in to the unused hole and install the base plastic (with the included mounting screws and plugs).
  • Page 4 3) When the heated area is >50 C. All the above faults are indicated as long as they exist. When they are restored, they will be erased and not indicated by the indication LEDs. LED MODULE CHARACTERISTICS GR-938/30L/LT GR-939/30L/LT Manufacturer Olympia Electronics S.A Model Number 0505175/30L Voltage Range 14-16.5V DC Nominal Power 5.4W...
  • Page 5: Warranty

    Olympia Electronics reserves the right to repair or to replace the returned goods and to or not charge the buyer depending on the reason of defection. Olympia Electronics reserves the right to charge or not the buyer the transportation cost.

This manual is also suitable for:

Gr-938/30l/lt