11. Advanced setup options for the M 7200 SW
Figure: Determining the high-end frequency cut-off
value(example: 180 Hz)
Subwoofer – High-end filter order
Figure: High-end filter order, Set 1
The filter order specifies the change in level relative
to the frequency, i.e., it indicates the "slope" of the
frequency curve. The high-end filter order indicates
the level decrease at the high end of the frequency
curve. A first-order filter decreases the signal level
by 6 decibels per octave (dB/oct). An "octave" is the
point where the frequency is doubled(octave above)
or halved(octave below). Each filter order decreases
the slope of the level change by -6 dB:
The maximum slope available is -24 dB/oct, i.e., a 4
order filter. Press "Enter". The
that the new setting has been applied.
24 Teufel · LT 7
1
order:
6 dB/oct
st
2
order:
12 dB/oct
nd
3
order:
18 dB/oct
rd
4
order:
24 dB/oct
th
Figure: High-end filter order(e.g., 3
order
st
th
symbol indicates
order)
rd