6. Locate the wrist strap (shipped with the PCI card), and attach its adhesive
copper strip to the chassis back panel. Wrap the other end twice around your
wrist, with the adhesive side against your skin.
7. Remove the filler panel from the back panel of the system chassis.
8. Locate a PCI card slot for Sun FastEthernet card.
Use Slot 2, unless that slot is already in use.
TABLE 1–1
PCI Card Slot:
Slot 1 J1301
Slot 2 J1401
Slot 3 J1501
Slot 4 J1601
These slots are illustrated in Figure 1–4. The Sun FastEthernet card shipped in the
upgrade kit is a 33 MHz card and thus cannot take advantage of the 66 MHz
capability of slot 1 (J1301). It should be installed in slot 2 (J1401). If that slot is not
available use slot 3 (J1501), or slot 4 (J1601).
Note -
manuals assume that the second network interface is installed in slot 2 (J1401).
Netra Proxy Cache 1.0 Server to Array Upgrade Instructions ♦ Revision A, March 1998
6
PCI Card Slots
Operating
Frequency
33 MHz or 66
MHz
33 MHz
33 MHz
33 MHz
Examples that follow in this document and in the Netra Proxy Cache Array
Input/Output Signaling Level:
3.3 volts
5.0 volts
5.0 volts
5.0 volts
Usable for
Array
Upgrade?
No
Yes
Yes
Yes