8. Trouble Shooting
Alarm Message
Failure description
ILeak-PRO
Leakage current protection
01/02/03/04
Relay check fail
RelayChk-FAIL
DCinj-FAULT
High DC injection current
Table 8.1 Fault message and description
NOTE:
If the inverter displays any alarm message as listed in Table 8.1; please
turn off the inverter (refer to Section 5.2 to stop your inverter) and wait for 5
minutes before restarting it (refer to Section 5.1 to start your inverter). If the
failure persists, please contact your local distributor or the service center.
Please keep ready with you the following information before contacting us.
1. Serial number of Canadian Solar Single Phase Inverter;
2. The distributor/dealer of Canadian Solar Single Phase Inverter (if available);
3. Installation date.
4. The description of problem (i.e. the alarm message displayed on the LCD and the status
of the LED status indicator lights. Other readings obtained from the Information submenu
(refer to Section 6.2) will also be helpful.);
5. The PV array configuration (e.g. number of panels, capacity of panels, number of strings
, etc.);
6. Your contact details.
.40.
Solution
1.Check AC and DC connection
2.Check inverter inside cable connection.
1.Restart inverter or contact installer.
1.Restart inverter or contact installer.
Model
Max. DC input power (Watts)
Max. DC input voltage (Volts)
Rated DC voltage (Volts)
Startup voltage (Volts)
MPPT voltage range (Volts)
Max. input current (Amps)
Max short circuit input current (Amps)
MPPT number/Max input strings number
Rated output power (Watts)
Max. output power (Watts)
Max. apparent output power (VA)
Rated grid voltage (Volts)
Grid voltage range (Volts)
Rated output current (Amps)
Power Factor (at rated output power)
THDi (at rated output power)
Rated grid frequency (Hertz)
Operating frequency range (Hertz)
Max.efficiency
EU efficiency
MPPT efficiency
Dimensions
Weight
Topology
Operating ambient temperature range
Ingress protection
Noise emission (typical)
Cooling concept
Max.operation altitude
Designed lifetime
Grid connection standard
Operating surroundings humidity
Connention
Display
Communication connections
Monitoring
Warranty Terms
Maximum inverter Backfeed Current to Array
Inrush Current (peak and duration)
Maximum Output Fault Current
Maximum Output Over Current Protection
CSI-4KTL1P-GI-FL
4600
600
330
120
90...520
11+11
17.2+17.2
2/2
4000
4400
4400
220/230
160...285
18.2/17.4
0.8leading~0.8lagging
<1.5%
50/60
47...52 or 57...62
98.1%
97.3%
>99.5%
310W*543H*160D (mm)
11.5kg
Transformerless
-25℃...60℃
IP65
<20 dBA
Natural convection
4000m
>20 years
En50438, G83/2, G98, G99, AS4777.2:2015,
VDE0126-1-1, IEC61727, VDE N4105
0...100% Condensing
Mc4 connector and Ip67 rated plug
LCD, 2×20 Z.
4 pins RS485 connector
WiFi or GPRS
5 Years STD (Extendable to 20 Years)
0 A
8.6A@5ms
51.3A
51.3A